arcattackandClaude Opus 5 08977ff128 Gitea #55: respawn now restores COOLANT / heat / generator state (+ a Generator reset re-transcribed from the binary)
THE GAP: Mech::Reset sweeps every subsystem with the virtual DeathReset
(mech4.cpp:1789), but only 7 weapon/ammo classes overrode it -- the entire
heat/coolant/power family fell through to the empty Subsystem::DeathReset base
(SUBSYSTM.h:161), so the respawn reset was a SILENT NO-OP for them.  All the
ResetToInitialState bodies already existed; nothing ever called them.  Hence the
field report: 'respawned with drained coolant'.

Added DeathReset forwarders (ResetToInitialState is not virtual, so each class
with its own body needs one): HeatableSubsystem, HeatSink, Condenser,
PoweredSubsystem, Generator.  HeatSink's also serves Reservoir -- the coolant
tank -- which has no body of its own; that is the one that refills coolant.

TWO MIS-TRANSCRIPTIONS FIXED, both verified against the binary with capstone:

1. HeatSink::ResetToInitialState chained HeatableSubsystem::ResetToInitialState
   with the comment 'FUN_004ac22c'.  But @004ac22c is Subsystem's terminus --
   disassembled: it reads the damage zone at this+0xe0, clears zone+0x158, and
   Set_Alarm_Levels zone+0x10 and this+0x2c to 0.  And the binary's HeatSink
   @004ad760 calls only @004ad884 (ClearHeatFilter), @004ad7f0 (UpdateHeatLoad)
   and @004ac22c -- never HeatableSubsystem.  Worse, HeatableSubsystem's body sets
   currentTemperature = 300.0f, CLOBBERING the startingTemperature that HeatSink
   assigned four lines earlier.  Dropped the call; the terminus work is already
   done for every subsystem by MechSubsystem::RespawnRepair (mech4.cpp:1790).

2. Generator::ResetToInitialState chained HeatableSubsystem and set
   outputVoltage = 0 -- which matches GNRATOR.TCP, but BT's BINARY DIVERGES from
   the TCP source, and the binary is what shipped.  Disassembled @004b215c
   instruction by instruction: it chains HeatSink (so the coolant refill DOES run
   for a generator), then generatorOn=1, startTimer=0, stateAlarm 0 then 2,
   **outputVoltage = ratedVoltage**, coolantAvailable=1, coolantFlowScale=1.0,
   startTimer=startTime.  Every offset matches our declared members exactly.
   The old version brought generators back from a respawn at ZERO output voltage,
   so energy weapons could never charge -- no recharge ring, no ready dot, nothing
   damaged.  That is a strong candidate for #54 (David's three dead lasers).

LIVE VERIFICATION (sim3.py, 3 mechs + force damage): 4 death/respawn cycles, and
every heat sink logged coolant == capacity on every respawn, with temp restored to
startingTemperature (77) rather than the clobbered 300.  Left as a silent
regression guard that only speaks if a respawn leaves coolant short.

KNOWN REMAINING [T3, noted in code]: Condenser's body chains HeatableSubsystem
rather than HeatSink, so a coolant loop's VALVE DETENT may still persist across a
respawn -- the binary's Condenser reset is not yet decompiled.  Do not claim
valves are fixed.