This website requires JavaScript.
Explore
Help
Register
Sign In
vwemirror
/
BT411
Watch
1
Star
0
Fork
0
Code
Issues
Pull Requests
Actions
Packages
Projects
Releases
Wiki
Activity
Files
7fa6dc536ce92669d8cfe00afe135effa7148a66
BT411
/
game
T
History
Joe DiPrima
and
Claude Fable 5
7fa6dc536c
#135
FIXED, two defects: (1) the generator lamp special was mis-reconstructed -- the binary @004cc27c is table_0051d070[generatorNumber] (bytes {0x29,0x1A..0x1D}, 1-based A..D, same shape as the condenser special), not an aux-screen placement probe generators never fill; a leaking generator now flashes its own lamp (benched: '[lamp] 0x1a <- 0x37 (FLASHING)' on a GeneratorA leak; was the field-logged 'NO LAMP RESOLVED'). (2) the eternal loop-button flash: Lamp::SetAlertState/SetState drop their panel notify when the edge lands off-page or in the one-frame mask race of a page transition, and the panel value latches the last-asserted flash forever -- Oracle's 'Loop 6 NEVER stopped' with Condenser6 SET/CLEARED balanced 3/3 in his log (the alarm manager was right; the lamp was stale). The skipped notify is now remembered and delivered at the lamp's next in-mode frame. KB: decomp-reference gains the 0x51d070 table + the stale-flash gotcha.
...
Co-Authored-By: Claude Fable 5 <
noreply@anthropic.com
>
2026-08-11 17:08:48 -05:00
..
fwd
Initial commit: bt411 -- standalone Windows BattleTech (Tesla 4.10 port)
2026-07-05 21:03:40 -05:00
glass
#169
rider: shorten the roster build-gate tag to [WRONG BUILD] -- the '-- WILL NOT LAUNCH' tail clipped at the 536px row edge (caught in the layout preview render)
2026-08-11 15:55:23 -05:00
original
SeekVoltageGraph: full reconstruction -- the eng-page POWER graph + top-box eraser (Gitea
#11
)
2026-07-19 20:27:39 -05:00
reconstructed
#135
FIXED, two defects: (1) the generator lamp special was mis-reconstructed -- the binary @004cc27c is table_0051d070[generatorNumber] (bytes {0x29,0x1A..0x1D}, 1-based A..D, same shape as the condenser special), not an aux-screen placement probe generators never fill; a leaking generator now flashes its own lamp (benched: '[lamp] 0x1a <- 0x37 (FLASHING)' on a GeneratorA leak; was the field-logged 'NO LAMP RESOLVED'). (2) the eternal loop-button flash: Lamp::SetAlertState/SetState drop their panel notify when the edge lands off-page or in the one-frame mask race of a page transition, and the panel value latches the last-asserted flash forever -- Oracle's 'Loop 6 NEVER stopped' with Condenser6 SET/CLEARED balanced 3/3 in his log (the alarm manager was right; the lamp was stale). The skipped notify is now remembered and delivered at the lamp's next in-mode frame. KB: decomp-reference gains the 0x51d070 table + the stale-flash gotcha.
2026-08-11 17:08:48 -05:00
btl4main.cpp
#163
round-end freeze + hang-on-exit FIXED: bare ExitProcess ran DLL detach with live Steam threads (no SteamAPI_Shutdown existed anywhere) and intermittently deadlocked -- the dead process's fullscreen frame squatted on screen while its menu child hung in SteamAPI_Init against the wedged sibling (field-captured, ZEUS 22:12:38). Ordered exit everywhere: flush forensics, BTSteamNet_ShutdownAll BEFORE the child spawns, hide our windows, TerminateProcess (detach skipped, deadlock structurally unreachable). Audit ledger: docs/MISSION_END_AUDIT_20260811.md (also yields
#156
's fade root cause). Bench: relaunch_bench.sh -- old pids dead, menu children clean
2026-08-11 01:58:23 -05:00