CydandClaude Fable 5 44aa7a349c BT410 5.3.38: SegmentArc270 never applied its 270 degrees
The class computed segmentSpan = 0.75 in its ctor and nothing ever read it:
the engine SegmentArc base has no span member, and SegmentArc270 declared no
Execute, so the recharge dial lit all 20 segments at PercentDone 1.0 where
the shipped cockpit lights 15 and leaves the quarter gap.  That was the last
MFD delta -- four extra spokes at the upper-left of every weapon disc.

A derived Execute is the only place the 0.75 can reach the draw, which is the
same role SegmentArcRatio's Execute plays with its own copy.  It scales the
raw fraction, draws, then restores: the connection only rewrites currentValue
when its source changes, so scaling in place would compound frame after frame
and walk the dial to zero.

  head   missing        extra
  Mfd1    140 (=)       679 -> 7
  Mfd2     97 (=)       462 -> 14
  Mfd3     31 (=)       461 -> 13

Cockpit: 98.2% identical / 97% coverage.  The three MFD heads and the three
engineering heads are now within a few dozen pixels of the shipped binary.