context-system housekeeping: the 2026-08-11 wave lands in the digests -- router Current-front refreshed + the four audit ledgers listed + the docs/ AI-vs-human split labeled; test-harness gains the standing bench-suite table (kd4/kd8/proj_ttl/gen_edge/xfire + rig notes: clone-the-pilot-page pattern, only map-defined dropzones are valid); multiplayer gains the K/D authority + #45 mirror section with the 4/8-node stress record; combat-damage gains the synchronous-death-transition section (gotcha 25 pointer, tripwire semantics); open-questions replicant-delivery entry gains the 0-of-35-deaths bench datapoint (needs field conditions); the #154 multi-agent audit lanes preserved from session temp as docs/GEN_WARNING_AUDIT_20260811.md (with the no-speech retraction lens noted). checkctx: CLEAN.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Fable 5
parent
4b986af94d
commit
2938d4918c
@@ -10,12 +10,15 @@
|
||||
`BTL4OPT.EXE` binary on top of the working WinTesla engine.
|
||||
**Repo of record:** the top-level `CMakeLists.txt` + `README.md` build `btl4.exe`. Layout:
|
||||
`engine/ game/ content/ docs/ reference/ tools/ context/`.
|
||||
**Current front (2026-08-06):** core gameplay reconstruction is COMPLETE — SP+MP loop, combat/
|
||||
damage/scoring, locomotion (gait/gimp/CROUCH), night kit (searchlight), death/respawn, replication
|
||||
all authentic + benched (builds 4.11.774→801). The decomp export was REBUILT 2026-08-06 (#60
|
||||
closed: coverage 93.5%, dark code 41 KB — cite `@ADDR`, NOT `part_0NN.c:LINE`; the old export is
|
||||
archived). Active work: the POLISH list. Details + what's-next: `context/project-overview.md`,
|
||||
`context/open-questions.md`, recent git log.
|
||||
**Current front (2026-08-11):** core gameplay reconstruction is COMPLETE and the K/D chain is
|
||||
STRESS-PROVEN (kd4/kd8 benches: receipt-derived invariants exact at 4 and 8 nodes, gotcha §25
|
||||
closed the same-frame double-credit). This week's settled fronts: projectile flight clocks +
|
||||
live-target contact (#168), generator-out voice at the trip (the port's ONE content deviation,
|
||||
#154), annunciator lamp table + stale-flash heal (#135), ordered exit (#163), ram eligibility
|
||||
(#128). The decomp export was REBUILT 2026-08-06 (#60 closed: coverage 93.5% — cite `@ADDR`,
|
||||
NOT `part_0NN.c:LINE`). Active work: field verification (8-player night) + the remaining
|
||||
POLISH list (#156 fade, weapon-state presentation). Details + what's-next:
|
||||
`context/project-overview.md`, `context/open-questions.md`, recent git log.
|
||||
|
||||
---
|
||||
|
||||
@@ -92,7 +95,11 @@ precise than anything you can infer.
|
||||
| Term / acronym definitions | `reference/glossary.yaml` |
|
||||
| The ORIGINAL 1995 player manual (controls, per-mech stats, coolant loops) | `reference/manual/Tesla40_BT_manual.pdf` (+ alignment audit in `context/pod-hardware.md` §Manual) |
|
||||
| The complete verbatim detail (fallback) | `docs/PROGRESS_LOG.md` (the old 2236-line CLAUDE.md) |
|
||||
| Detailed running ledgers | `docs/RECONCILE.md`, `docs/GAUGE_COMPOSITE.md`, `docs/HARD_PROBLEMS.md`, `docs/SUBSYS_PLAN.md`, `docs/P3_LOCOMOTION.md`, `docs/RESOURCE_AUDIT.md`, `docs/VEHICLE_SUBSYSTEMS.md`, `docs/BGF_FORMAT.md`, `docs/ASSET_PIPELINE.md`, `docs/BT_SOURCE_STATUS.md`, `docs/WAVE_PLAN.md`, `docs/GLASS_COCKPIT.md`, `docs/REVOLVING_DOOR_PLAN.md`, `docs/INPUT_PATH_AUDIT.md`, `docs/RESPAWN_REARM_PLAN.md`, `docs/KD_SCOREBOARD_PLAN.md`, `docs/DIST_LAYOUT_PLAN.md`, `docs/MOUSELOOK_PLAN.md`, `docs/GHOST_MECH_ANALYSIS.md` |
|
||||
| Detailed running ledgers | `docs/RECONCILE.md`, `docs/GAUGE_COMPOSITE.md`, `docs/HARD_PROBLEMS.md`, `docs/SUBSYS_PLAN.md`, `docs/P3_LOCOMOTION.md`, `docs/RESOURCE_AUDIT.md`, `docs/VEHICLE_SUBSYSTEMS.md`, `docs/BGF_FORMAT.md`, `docs/ASSET_PIPELINE.md`, `docs/BT_SOURCE_STATUS.md`, `docs/WAVE_PLAN.md`, `docs/GLASS_COCKPIT.md`, `docs/REVOLVING_DOOR_PLAN.md`, `docs/INPUT_PATH_AUDIT.md`, `docs/RESPAWN_REARM_PLAN.md`, `docs/KD_SCOREBOARD_PLAN.md`, `docs/DIST_LAYOUT_PLAN.md`, `docs/MOUSELOOK_PLAN.md`, `docs/GHOST_MECH_ANALYSIS.md`, `docs/AUDIO_FIDELITY.md`; multi-agent audit ledgers (2026-08-11): `docs/KD_CHAIN_AUDIT_20260811.md`, `docs/MISSION_END_AUDIT_20260811.md`, `docs/RAM_LEAK_AUDIT_20260811.md`, `docs/GEN_WARNING_AUDIT_20260811.md` |
|
||||
|
||||
**`docs/` split note:** most of `docs/` is AI-facing DETAIL (the ledgers above + `PROGRESS_LOG.md`);
|
||||
the HUMAN-facing subset is exactly `OPERATOR_GUIDE.md`, `OPEN_ISSUES_FOR_TESTERS.txt`, and
|
||||
`dist/RELEASE_NOTES_*` — write for the right audience per file.
|
||||
|
||||
---
|
||||
|
||||
|
||||
@@ -1261,6 +1261,16 @@ code involved; grammar = the binary ctors @0x49ea48/@0x49e5e4). Results:
|
||||
cylinder** -- diverted at the handler head (0x4a0361: test type; 0x4a036d:
|
||||
call 0x49ffcc; jmp out) [T1 disasm].
|
||||
|
||||
## The death transition is SYNCHRONOUS within the damage pass (2026-08-11) [T1/T2]
|
||||
The binary writes movementMode 9 INSIDE the lethal TakeDamage pass — its own death-tail gate
|
||||
(part_012.c:14761) reads 9||10 already flipped in the same call. The port deferred the write to
|
||||
the per-frame UpdateDeathState and a same-frame direct+splash lethal pair re-ran the whole death
|
||||
block (duplicate kill credit + duplicate VehicleDead) — caught by the 4-node bench, fixed by
|
||||
running the once-per-death transition inline at the death tail (1b6d247). Full class write-up:
|
||||
[[reconstruction-gotchas]] §25; stress verification: kd4_bench 9/9/9/9 + kd8_stress 26/26/26/26,
|
||||
SWALLOWED=0 both. The receiver-side dedup remains a TRIPWIRE only (1995 has none; +0x290 never
|
||||
written) — if it ever fires again, a new duplicate source exists upstream.
|
||||
|
||||
## Key Relationships
|
||||
- Weapons/roster: [[subsystems]]. Aim source: [[locomotion]] (drive/facing). Effects: [[rendering]].
|
||||
- P5 forensics: `docs/HARD_PROBLEMS.md`. Data: [[decomp-reference]] §4-5.
|
||||
|
||||
+14
-1
@@ -907,4 +907,17 @@ RECONSTRUCTION STATE: coupled path is DEFAULT ON (mech4.cpp: s_drPos gait-couple
|
||||
|
||||
|
||||
## Peer motion: the "random shakiness" is single-box packet jitter, NOT the game (task #50, 2026-07-15) [T2]
|
||||
After the coupled body-channel peer landed (96a896a + turn-step f094d78 + cadence-mirror 23f1532), residual peer shakiness on accel/decel was RANDOM -- sometimes perfect, sometimes shaky. Root cause is the TEST RIG, proven with BT_RXJIT (record inter-arrival ms on the peer): two Debug btl4 nodes on ONE box contend for CPU, so Windows BATCHES their TCP delivery -- update records arrive in bursts (min ~0ms back-to-back, max 56-226ms gaps, burstiness max/avg 3-7x) instead of an even ~17ms. A peer dead-reckons across the long gaps then snaps when a record lands -> random shake. Pinning each node to a DISJOINT core set (ProcessorAffinity 0x00F / 0x3C0) restored even ~17ms delivery (burstiness ~1.0) and the shakiness vanished (user-confirmed). REAL pods are dedicated machines with no contention -- they never see this. DO NOT add an interpolation/jitter buffer or other un-authentic netcode to mask a single-box artifact. Use tools/mp_launch.sh (bakes in the affinity) for all 2-node tests. Diagnostic env: BT_RXJIT (arrival jitter), BT_SLIDE ([slide]/[mslide] slide-in-stand), BT_GAITEV, BT_MIRDIV, BT_NO_MIRROR_CAD / BT_PEER_LEGCH (revert the coupled-peer fixes).
|
||||
After the coupled body-channel peer landed (96a896a + turn-step f094d78 + cadence-mirror 23f1532), residual peer shakiness on accel/decel was RANDOM -- sometimes perfect, sometimes shaky. Root cause is the TEST RIG, proven with BT_RXJIT (record inter-arrival ms on the peer): two Debug btl4 nodes on ONE box contend for CPU, so Windows BATCHES their TCP delivery -- update records arrive in bursts (min ~0ms back-to-back, max 56-226ms gaps, burstiness max/avg 3-7x) instead of an even ~17ms. A peer dead-reckons across the long gaps then snaps when a record lands -> random shake. Pinning each node to a DISJOINT core set (ProcessorAffinity 0x00F / 0x3C0) restored even ~17ms delivery (burstiness ~1.0) and the shakiness vanished (user-confirmed). REAL pods are dedicated machines with no contention -- they never see this. DO NOT add an interpolation/jitter buffer or other un-authentic netcode to mask a single-box artifact. Use tools/mp_launch.sh (bakes in the affinity) for all 2-node tests. Diagnostic env: BT_RXJIT (arrival jitter), BT_SLIDE ([slide]/[mslide] slide-in-stand), BT_GAITEV, BT_MIRDIV, BT_NO_MIRROR_CAD / BT_PEER_LEGCH (revert the coupled-peer fixes).
|
||||
## K/D authority + the scoreboard mirror — STRESS-PROVEN at 4 and 8 nodes (2026-08-11) [T2]
|
||||
The scoring authority model (full map: [[combat-damage]] + `docs/KD_CHAIN_AUDIT_20260811.md`):
|
||||
the VICTIM's master emits everything on its death edge (kill credit to the shooter via
|
||||
replicant-Dispatch reroute, received penalty to itself, one VehicleDead); the killer's master
|
||||
increments `killCount` when the rerouted credit lands; **killCount/deathTally never crossed the
|
||||
1995 wire** — the port's #45 update-record extension mirrors them one-way owner→replicant
|
||||
(read guarded replicant-only, mixed-version length guard, 2s heartbeat re-dirty). Bystander
|
||||
nodes learn tallies ONLY through that mirror. Verified: `kd4_bench.sh` (bystander convergence +
|
||||
no-mirror-exceeds-authority, receipt-derived per player) and `kd8_stress.sh` (8-node all-vs-all
|
||||
melee, 26 deaths: 26/26/26/26 with zero duplicate-death swallows and zero `inst=R` deliveries).
|
||||
The same-frame double-credit this closed (direct+splash lethal pair racing the deferred death
|
||||
transition) is gotcha §25 — the death mode now flips synchronously inside the damage pass,
|
||||
matching part_012.c:14761.
|
||||
|
||||
@@ -1190,3 +1190,7 @@ replicant-side execution may have OTHER un-audited side effects (zone/subsystem
|
||||
on peer copies beyond the intended visual application). To close: instrument the entry with the
|
||||
delivery path (who posted it, from which socket/queue), find the first build where inst=R rows
|
||||
appear, and decide whether the delivery is intended (visual-damage design) or a seam bug.
|
||||
DATAPOINT (2026-08-11, the #162 retest wave): the kd4/kd8 benches audit this explicitly (I8)
|
||||
and saw **0 inst=R DMG rows across three 4-node runs and one 8-node melee** (35 deaths total)
|
||||
on build ~900 -- the behavior did not reproduce on the bench rig; whatever produced the
|
||||
night-15 field rows needs field conditions (steam wire seam?) the LAN relay path lacks.
|
||||
|
||||
+18
-1
@@ -204,7 +204,24 @@ sleep <duration>; kill $relay; bt_kill_ours
|
||||
your own legs; pair screenshots with a state probe and READ a frame before concluding.
|
||||
- **Build ritual first** — see [[build-and-run]] §Build ritual (stale exe = phantom results).
|
||||
|
||||
## The standing bench suite (scratchpad/night15/, 2026-08-11 wave — all hard PASS/FAIL)
|
||||
| Bench | Asserts | Hooks it rides |
|
||||
|---|---|---|
|
||||
| `kd_bench.sh` (2-node) | K/D invariants I1-I5: deaths == PLAYER_DEAD == −500 costs == kill credits, no swallows | BT_AUTOFIRE + BT_AF_MISSILE, BT_GOTO, matchlog |
|
||||
| `kd4_bench.sh` (4-node) | I1-I8 **receipt-derived per player** + bystander mirror convergence + no-mirror-exceeds-authority + zero `inst=R` | same + SBMIRROR records |
|
||||
| `kd8_stress.sh` (8-node) | the same invariants under an all-vs-all melee (staggered salvo periods, one drop zone); `LOW STRESS` guard | same, 8 instances 1 core each |
|
||||
| `proj_ttl_bench.sh` | #168 flight clocks: probe fizzles at exactly 5.0s / burn+10s; field phase: authentic ttl stamps, none early, no stale-point hits | BT_PROJ_TEST probe + BT_PROJ_LOG |
|
||||
| `gen_edge_bench.sh` | #154 warning edge: 4/4 trigger fixups, trip edge FIRED, recovery + respawn silent | BT_GEN_HEAT injection + BT_AUDIO_EDGE |
|
||||
| `xfire_bench.sh` | #165 destroyed-weapon gate: pre-kill FIRED, post-kill only REFUSED, survivor unaffected | BT_KILL_SUBSYS + named `[emitter] FIRED` |
|
||||
| `eject_canary.sh` / `ram_bench.sh` / `relaunch_bench.sh` | eject suicide arithmetic / ram-rattle eligibility set / ordered-exit no-zombies | (night-15 fix wave) |
|
||||
|
||||
Multi-node rig notes: extend the egg by CLONING the 1602 pilot page (the kd4/kd8 scripts show
|
||||
the python pattern); **only zone names the MAP defines are valid dropzones** (undefined names
|
||||
pile everyone at a fallback — mechs spawn overlapping and the melee turns into splash-suicide
|
||||
chaos, which the receipt-derived invariants still score exactly, but it isn't the scenario you
|
||||
wrote); affinity masks 2-cores-each up to 4 nodes, 1-each at 8.
|
||||
|
||||
## Key Relationships
|
||||
- Uses: [[build-and-run]] (parity, env gates, BT_SHOT capture) · [[experience-levels]] (expert vs novice gating)
|
||||
- Informs: [[reconstruction-method]] (step 4 "verify honestly" — this file is the how)
|
||||
- Incident sources: [[reconstruction-gotchas]] §23 (pixels), §26 (silent stubs); [[multiplayer]] (replication layers)
|
||||
- Incident sources: [[reconstruction-gotchas]] §23 (pixels), §25 (same-pass latch timing — caught by the 4-node bench), §26 (silent stubs); [[multiplayer]] (replication layers)
|
||||
|
||||
@@ -0,0 +1,507 @@
|
||||
# Generator-Out Warning Audit — #154 (2026-08-11)
|
||||
|
||||
> **Ledger** (full multi-agent evidence record; the curated digest lives in
|
||||
> `context/decomp-reference.md` §Generator trip/recovery + the warning edge).
|
||||
> Verdict chain: recovery threshold AUTHENTIC (trip 2000 / re-arm 1000 = the
|
||||
> manual p23 half-cooled rule, heat-bar red == the gate); the warning was
|
||||
> AUTHORED on the leave-GeneratorOut edge in shipped BTL4.RES (the game's only
|
||||
> inverse-Start fault trigger, 144-row census) — fixed as the port's one
|
||||
> deliberate content deviation (08fc87e, `BT_GEN_WARN_SHIPPED=1` reverts);
|
||||
> live-benched trip-FIRED/recovery-silent (gen_edge_bench.sh); phrase
|
||||
> ear-verified as Yip's spoken "generator out" (fef6fad).
|
||||
>
|
||||
> ⚠ RECORD CORRECTION (8d2f482): a same-day claim that BT 4.10 shipped no
|
||||
> speech (and that era memories were Firestorm's) was WRONG — the Warnings01
|
||||
> zones ARE the voice, phrase-sequenced (#119, commit 42b0691). The claim
|
||||
> below in lane text predates the correction; read it with that lens. Process
|
||||
> lesson recorded in memory: grep the project's own git log before asserting
|
||||
> an asset absent.
|
||||
|
||||
---
|
||||
|
||||
## Phase 1 — four investigation lanes (raw returns)
|
||||
|
||||
|
||||
########## LANE 0 ##########
|
||||
## #154 — OUR PORT's generator trip/recovery reconstruction (raw findings)
|
||||
|
||||
### 1. Trip + recovery logic and thresholds
|
||||
|
||||
The generator's thermal trip lives in `Generator::GeneratorSimulation` — C:/git/bt411/game/reconstructed/powersub.cpp:1295-1372, transcribed from @004b1f7c (raw: reference/decomp/all/part_013.c:9049-9107, re-read this session).
|
||||
|
||||
TRIP (powersub.cpp:1304-1312):
|
||||
```cpp
|
||||
if (heatAlarm.GetLevel() == HeatSink::FailureHeat) // this+0x184 == 2
|
||||
{
|
||||
...
|
||||
stateAlarm.SetLevel(GeneratorOut); // SetLevel 4
|
||||
}
|
||||
```
|
||||
This is a HELD condition, not an edge: it re-asserts SetLevel(4) EVERY frame while heatAlarm==FailureHeat. Binary identical [T1]: part_013.c:9062-9064 `if (param_1[0x61] == 2) FUN_0041bbd8(param_1+0x7f, 4);`.
|
||||
|
||||
RECOVERY (powersub.cpp:1340-1357):
|
||||
```cpp
|
||||
case GeneratorOut: // 4
|
||||
outputVoltage = 0.0f;
|
||||
if (heatAlarm.GetLevel() == HeatSink::NormalHeat) // this+0x184 == 0
|
||||
{
|
||||
if (generatorOn == 0) { stateAlarm.SetLevel(GeneratorIdle); } // 1
|
||||
else { startTimer = 0.0f; stateAlarm.SetLevel(GeneratorStarting); } // 0
|
||||
}
|
||||
```
|
||||
Binary identical [T1]: part_013.c:9087-9097 (`param_1[0x61] == 0` gate, generatorOn at [0x75]). After the spin-up (`startTime <= startTimer`) it goes `SetLevel(GeneratorReady)` (2) and recomputes `outputVoltage = (1.0 - SourceLevel()) * ratedVoltage` (powersub.cpp:1316-1324).
|
||||
|
||||
The temperature thresholds behind heatAlarm (heat.cpp:851-862, @004ad924 [T1]): `T > failureTemperature → FailureHeat(2)`, `T > degradationTemperature → DegradationHeat(1)`, else `NormalHeat(0)`. Pure per-frame comparison, NO hysteresis. So: **trip at T > failureTemperature; recovery gate at T ≤ degradationTemperature** (all the way out of the yellow band, not just the red).
|
||||
|
||||
**The tester's era rule ("back online at HALF-cooled, when the red portion of the heat bar is gone") is SATISFIED by the port as built — no divergence.** The generator heat bar is a `VertTwoPartBar` fed `(currentTemp, degradeTemp, failTemp)` (btl4gau2.cpp:980-998); its Execute (btl4gaug.cpp:1321-1360, @004c48fc [T1]) tiles the bar up to the warn pixel `height*low/high` (low=degradationTemperature, high=failureTemperature) and paints `fillColor` only in the degradation..failure segment — i.e. the "red portion" IS exactly the T>degradationTemperature band, and it disappears exactly when the recovery gate opens. With the authored profile degradation=1000/failure=2000 (myomer record from BTL4.RES; generator values not separately confirmed [T3]) the warn line sits at literally HALF the bar. Oracle's 2nd/3rd tests ("came back after cooling halfway") behaviorally confirm the port already does this [T2-field].
|
||||
|
||||
### 2. stateAlarm writers, edges, and marks
|
||||
|
||||
Complete writer inventory of `Generator::stateAlarm` (@0x1FC, level cell @0x210):
|
||||
- powersub.cpp:1311 `SetLevel(4)` — thermal breaker, HELD (per-frame re-assert while FailureHeat). The edge-ification happens inside the alarm: `GaugeAlarm54::SetLevel` (heat.hpp:106) `{ levelB = level; if (n != level) { level = n; NotifyWatchers(); } }` — notify ONLY on change, oldState (levelB@0x10) updated UNCONDITIONALLY. Byte-matches the binary FUN_0041bbd8 [T1] (part_002.c:5512-5546: `+0x10 = +0x14` before the equality check, then the three watcher sockets @+0x18/+0x2c/+0x40 fire only on change) and the T0 engine `StateIndicator::SetState` (engine/MUNGA/SIMULATE.cpp:155-217, including the "old state changes even on no-op set" NOTE at :176-179).
|
||||
- powersub.cpp:1302 `SetLevel(1)` — held while `simulationState==1` (destroyed): a crit-destroyed generator is PINNED Idle forever (authentic).
|
||||
- powersub.cpp:1321/1335 `SetLevel(2)` — spin-up / short-recovery completion.
|
||||
- powersub.cpp:1346/1354 — the recovery arm above (4→1 or 4→0).
|
||||
- powersub.cpp:1392 `SetLevel(3)` — HandleMessage msg 4 short (@004b21d0 [T1]).
|
||||
- powersub.cpp:1212/1221 — ToggleGeneratorOnOff (@004b1ed0, raw re-read part_013.c:9016-9045 [T1]): OFF → SetLevel(1); ON → SetLevel(0) ONLY if heatAlarm==0 (hot ON-press changes NO state — see §4).
|
||||
- powersub.cpp:1269-1270 — ResetToInitialState (@004b215c [T1]): SetLevel(0) then SetLevel(2) — every respawn passes through Starting then Ready.
|
||||
- powersub.cpp:555 + :1564 — `ForceShortRecovery`/`PowerWatcher::HandleMessage` write `source->stateAlarm.SetLevel(3)` externally.
|
||||
- `MarkGeneratorOut()` (powersub.hpp:483) via `BTGeneratorMarkOut` (powersub.cpp:1787-1791): **ZERO live callers** — the ForceCriticalFailure call was removed 2026-08-03 (mechsub.cpp:290-297).
|
||||
|
||||
**Edge delivered to audio:** the trip produces a synchronous `StateChanged(prev→4)` on the trip frame. Mechanism: `ATTRIBUTE_ENTRY(Generator, GeneratorState, stateAlarm)` (powersub.cpp:1051) publishes the alarm; `AudioStateWatcher` registers on the alarm's +0x18 audio socket (engine/MUNGA/AUDWTHR.cpp:918, with the T3 bring-up guard :908-917 that a constructed GaugeAlarm54 passes); `NotifyWatchers` (heat.cpp:96-111) Execute()s it inside SetLevel; `SendNotificationOfChange` (AUDWTHR.cpp:933-945) reads GetOldState()/GetState() at +0x10/+0x14 — layout verified compatible: StateIndicator : Node : Plug : RegisteredClass gives header 0xC then stateCount/oldState/currentState @0xC/0x10/0x14 + three sockets @0x18/0x2C/0x40 = 0x54, identical to GaugeAlarm54 (heat.hpp:126-138). State watchers are NOT on the per-frame poll socket (only `AudioTriggerOf`/`AudioMatchOf` call `simulation->AddAudioWatcher(this)` — AUDWTHR.h:293/:770; `AudioStateWatcher` registers only on the indicator socket), so no spurious held-state notifications.
|
||||
|
||||
**No ForceUpdate/updateModel/SetDirty mark exists at either edge** — grep of powersub.cpp finds none; the binary @004b1f7c has none either [T1]. The notification is purely the alarm-socket synchronous path.
|
||||
|
||||
**So the port's plumbing puts the notification on the TRIP edge (X→4), and also emits 4→0 then 0→2 at recovery.** Which of those the "Generator Out" SPEECH keys on is decided by the authored `AudioStateTrigger` fields (`triggerState/inverseTrigger/exclude_state`, streamed — AUDWTHR.cpp:968-990; firing rule :1046-1105 [T0]): non-inverse fires on `new_state==triggerState`, inverse on `old_state==triggerState` — an inverse trigger on state 4 fires EXACTLY on the recovery edge, which matches Oracle's symptom precisely. The port cannot flip this itself: the alarm mechanics are byte-faithful. The decisive probe is the load-time `[statecfg]` dump (AUDWTHR.cpp:981-987, env BT_ATTRBIND_LOG) — it prints every authored GeneratorState trigger's trigState/inv/exclude. Until that capture, whether the wrong edge is (a) authored-inverse consumed correctly (pod-era authoring quirk), (b) the trip-edge trigger authored against an attribute the port publishes differently, or (c) a dead START half of a start/stop pair, is undetermined FROM THIS LANE.
|
||||
|
||||
### 3. Divergence check vs the knowledge base
|
||||
|
||||
- context/decomp-reference.md:470-477 ("no Ready-case recompute"; stateAlarm 4's producer = the thermal breaker in GeneratorSimulation; the 2026-08-03 destruction→state-4 bridge removed as unfounded): **port conforms** — no Ready-case recompute exists in the port either, `BTGeneratorMarkOut` is dead code as documented.
|
||||
- context/subsystems.md:103-105 ("(1 − generator damage) × rated, thermal breaker on FailureHeat; NO load model"): consistent with powersub.cpp:1322/1336/1398.
|
||||
- One STALE-ish note found: powersub.cpp:1052's comment on GeneratorOn ("static until a shutdown writer drives it to 0") — the shutdown writer EXISTS now (ToggleGeneratorOnOff, powersub.cpp:1214/1223); the comment predates #53. Cosmetic.
|
||||
- No divergence found between the port and @004b1f7c/@004b1ed0/@004b215c/@0041bbd8 — instruction-shape faithful on every path I compared [T1].
|
||||
|
||||
### 4. FailureHeat "permanent brick" family (open-questions)
|
||||
|
||||
The generator does NOT share a recompute path with the weapon FailureHeat family — three distinct recovery disciplines all reading the SAME producer (own HeatSink heatAlarm @+0x184, thresholds heat.cpp:851-861):
|
||||
1. **Emitters** (@004baa88, emitter.cpp:225-229, :426-434): continuous per-tick gate — ResetFiringState + currentLevel=0 while heatAlarm==2, auto-resumes as soon as heatAlarm drops to 1 (DegradationHeat). Weapons recover at "red gone"; the generator demands full NormalHeat — an intentional binary asymmetry [T1].
|
||||
2. **Launchers** (open-questions.md:1086-1102, projweap gate-1): a LATCH (weaponAlarm 7 roach-motel, re-asserted unconditionally), recovery ONLY out-of-band via the EjectAmmo tap (@004bb9b8) or reset — never by cooling. This is the documented "missile spam brick".
|
||||
3. **Generator**: a state-machine arm (case 4) that self-clears at NormalHeat — the OPPOSITE of a latch.
|
||||
|
||||
Family resemblance that could explain the once-seen "stuck offline forever" (did not repro): the generator DOES have latch-shaped states with no thermal recovery arm, and both are binary-authentic [T1]:
|
||||
- **The Idle park**: press generator OFF then ON while heatAlarm==1 (degradation band). The ON branch (@004b1ed0, part_013.c:9027-9033) sets startTimer=0 but does NOT touch stateAlarm when hot → parked at Idle(1) with generatorOn=1; case 1 has no restart arm; the FailureHeat re-trip doesn't fire (heat is only level 1). Recoverable only by another OFF/ON cycle after full cooling, or reset. Requires eng-page button presses — plausible for Oracle's first test.
|
||||
- **Crit-destroyed generator**: `simulationState==1` pins Idle every frame (powersub.cpp:1300-1303) — permanently out, authentically. If trip #1 coincided with a generator crit, "never came back" is correct behavior.
|
||||
- Non-button path: T parked in the degradation band forever keeps the breaker latched — but then the bar still shows red, contradicting "cooled off completely"; the bar and the alarm read the same currentTemperature, so this one is self-consistent and unlikely.
|
||||
|
||||
Bench hooks already in place: `[gen] X TRIPPED (T=...)` / `[gen] X RESTARTING (T=...)` under BT_HEAT_LOG (powersub.cpp:1308-1310, 1350-1352) give the exact trip/recovery timeline to line up against the audio.
|
||||
--- KEY FACTS ---
|
||||
* Trip: powersub.cpp:1304-1312 — stateAlarm.SetLevel(GeneratorOut=4) re-asserted EVERY frame while own heatAlarm==FailureHeat(2), i.e. currentTemperature > failureTemperature; binary-identical @004b1f7c (part_013.c:9062-9064) [T1]
|
||||
* Recovery: powersub.cpp:1340-1357 — requires heatAlarm==NormalHeat(0), i.e. T <= degradationTemperature; then GeneratorStarting(0) -> spin-up startTime -> GeneratorReady(2) with outputVoltage=(1-SourceLevel())*ratedVoltage; binary-identical (part_013.c:9087-9097) [T1]
|
||||
* heatAlarm thresholds heat.cpp:851-862 (@004ad924): >failureT=FailureHeat(2), >degradationT=DegradationHeat(1), else NormalHeat(0); NO hysteresis [T1]
|
||||
* Era rule already satisfied: the generator heat bar (VertTwoPartBar, btl4gau2.cpp:980-998; Execute btl4gaug.cpp:1321-1360 @004c48fc) paints its fill ONLY in the degradationT..failureT segment — 'red portion gone' == T<=degradationT == the recovery gate; with authored deg=1000/fail=2000 the warn line is at half the bar [T1 code, T3 for generator-specific authored values]
|
||||
* Alarm edge semantics faithful: GaugeAlarm54::SetLevel (heat.hpp:106) == binary FUN_0041bbd8 (part_002.c:5512-5546) == engine StateIndicator::SetState (SIMULATE.cpp:155-217): oldState:=current unconditionally, notify watchers only on change [T0/T1]
|
||||
* Trip edge DOES notify audio synchronously in the port: StateChanged(prev->4) on the trip frame via the alarm's +0x18 audio socket (AUDWTHR.cpp:918, 933-945); recovery emits 4->0 then 0->2; layout GaugeAlarm54==StateIndicator verified (header 0xC, oldState@0x10, currentState@0x14, sockets 0x18/0x2C/0x40) [T0+T1]
|
||||
* No ForceUpdate/updateModel/SetDirty mark at either edge in port or binary; AudioStateWatcher/AudioStateTrigger are NOT on the per-frame poll socket (only AudioTriggerOf/AudioMatchOf call simulation->AddAudioWatcher — AUDWTHR.h:293/:770) [T0]
|
||||
* Which edge plays the voice is decided by authored AudioStateTrigger fields (triggerState/inverseTrigger/exclude_state, AUDWTHR.cpp:1046-1105): inverse trigger on state 4 fires exactly on the RECOVERY edge — matching Oracle's symptom; the [statecfg] dump under BT_ATTRBIND_LOG (AUDWTHR.cpp:981-987) prints every authored GeneratorState trigger config at load [T0 mechanism, T4 on which config is authored]
|
||||
* stateAlarm=4 writers: ONLY the thermal breaker; MarkGeneratorOut/BTGeneratorMarkOut (powersub.cpp:1787) has zero callers since 2026-08-03 (mechsub.cpp:290-297) [T2]
|
||||
* Stuck-offline candidates, all binary-authentic [T1]: (a) Idle park — generator ON pressed while heatAlarm==1: @004b1ed0 (part_013.c:9027-9033) sets no state when hot -> parked at Idle(1), no restart arm, FailureHeat re-trip cannot fire at level 1; (b) crit-destroyed generator pinned Idle every frame (powersub.cpp:1300-1303, simulationState==1)
|
||||
* FailureHeat family recompute paths are DISTINCT: emitter auto-resumes at heatAlarm<2 (@004baa88); launcher latches weaponAlarm 7, recovery only via EjectAmmo tap (@004bb9b8) or reset (open-questions.md:1086-1102); generator self-clears only at heatAlarm==0 — shared PRODUCER (own heatAlarm) but no shared recovery path [T1]
|
||||
* Weapons recover at DegradationHeat (red gone) but the generator requires NormalHeat — an intentional binary asymmetry, not a port bug [T1]
|
||||
* Bench hooks: BT_HEAT_LOG prints '[gen] X TRIPPED (T=..)' / '[gen] X RESTARTING (T=..)' (powersub.cpp:1308-1310, 1350-1352) for a trip/recovery-vs-audio timeline [T2]
|
||||
--- UNCERTAINTIES ---
|
||||
* The authored AudioStateTrigger config for Generator.GeneratorState (triggerState/inverseTrigger/exclude_state values) is unknown from this lane — it lives in the 1995 audio stream; the BT_ATTRBIND_LOG [statecfg] load-time dump would settle which edge the 'Generator Out' speech keys on. Until then, whether the wrong edge is authored-inverse (STOP half of a pair firing as the only live trigger) or a dead trip-side binding is T4.
|
||||
* Whether the 'Generator Out' voice is even bound to Generator.GeneratorState vs GeneratorOn (a live x4 attr that does NOT change on thermal trip) vs a PoweredSubsystem electrical-state attribute the binary published but the port does not (port publishes only InputVoltage on PoweredSubsystem, powersub.cpp:100-104) — unverified.
|
||||
* Generator-specific authored DegradationTemperature/FailureTemperature values: only the myomer profile (1000/2000, BTL4.RES) is confirmed; generators are authored per-subsystem in content and could differ, which would shift where 'half-cooled' sits on the bar.
|
||||
* Whether Oracle's once-seen stuck generator was crit-destroyed (authentic permanent-out), the Idle park (requires OFF/ON presses while in the yellow band), or something else — not reproducible from code reading; needs the field log for that session.
|
||||
* The AudioStateWatcher bring-up guard (AUDWTHR.cpp:908-917) is assumed to PASS for GaugeAlarm54 sockets (constructed SChainOf vptr at +0x18); AUDIO_FIDELITY F8's 'all 118 state watchers bind real StateIndicators' supports this, but a per-generator [audiostate] skip line under BT_AUDIO_LOG in the FIELD build has not been ruled out this session.
|
||||
* Prime-time notification (PrimeWatcher -> SendNotificationOfChange at audio-page bind if the streamed sendNotificationOnChange flag is set) delivers StateChanged(0,2) at load — whether any authored trigger misfires on that is unchecked.
|
||||
|
||||
|
||||
########## LANE 1 ##########
|
||||
## The binary's Generator state machine (issue #154 lane: BTL4OPT.EXE simulation)
|
||||
|
||||
### Object map (Generator, classID 0xBC1, ctor @4b225c, vtable 0x50fd74)
|
||||
The generator's operational state machine is a 0x54-byte StateIndicator at gen+0x1FC (ctor `FUN_0041b9ec(this+0x1FC, 5)` = 5 levels; current level @0x210 = the "stateAlarm", previous level @0x20C) [T1]. Fields set by the ctor @4b225c: ratedVoltage@0x1D8←res+0xFC, outputVoltage@0x1DC, maxTapCount@0x1E4←res+0x100, startTime@0x1EC←res+0x104, startTimer@0x1F0, shortRecoveryTime@0x1F4←res+0x108, shortTimer@0x1F8, generatorOn@0x1D4=1, percentAvailable@0x1D0=1.0, generatorNumber@0x1E0 = last char of name − 0x40 (A=1..D=4). Initial state = SetState(2) Ready [T1]. States (2=Ready confirmed by HasVoltage @4b0b5c requiring source+0x210==2; 3=short-recovery and 1/4=off/out confirmed by the consumer-side dump @4b1224 which maps source 3→"Shorted", source 1||4→"GeneratorOff"): 0=Starting, 1=Off/Idle, 2=Ready, 3=ShortRecovery, 4=GeneratorOut.
|
||||
|
||||
The heat alarm is a SECOND, separate 3-level StateIndicator at gen+0x170 (level @0x184), inherited from HeatableSubsystem (ctor @4adda0: `FUN_0041b9ec(this+0x170, 3)`), with debug names @4ae050: 0="NormalHeat", 1="DegradationHeat", 2="FailureHeat" [T1].
|
||||
|
||||
### 1. THE THERMAL TRIP — exact write site
|
||||
`GeneratorSimulation` = FUN_004b1f7c(this, dt) (part_013.c:9049-9107). Its preamble, every tick, BEFORE the state switch:
|
||||
- base call FUN_004ad924 (HeatableSubsystem sim) recomputes temperature@0x114 = heatContent@0x158 / thermalMass@0x154 and drives the heat alarm with NO hysteresis: `if (T > FailureTemperature@0x11C) SetState(heatAlarm,2); else if (T > DegradationTemperature@0x118) SetState(heatAlarm,1); else SetState(heatAlarm,0)` (part_013.c:5638-5646) [T1]. The thresholds are authored content: HeatSink ctor @4adda0 loads 0x114←res+0xE4 StartingTemperature, 0x118←res+0xE8 DegradationTemperature, 0x11C←res+0xEC FailureTemperature (parse @4ae150) [T1].
|
||||
- then `if (heatAlarm@0x184 == 2) SetState(genState@0x1FC, 4)` (part_013.c:9062-9064). **This is the ONLY producer of stateAlarm 4 in the binary** — I walked every SetState on the +0x1FC machine: ctor(2), ResetToInitialState @4b215c (0 then 2), toggle @4b1ed0 (0/1), sim @4b1f7c (1/4/2/2/1/0), HandleMessage msg-4 @4b21d0 (3), PoweredSubsystem-initiated short @4b11bc (3). No other site writes 4 [T1]. (The `SetState(+0x99,4)` calls in @4b0bd0/@4b0e6c are the CONSUMER PoweredSubsystem's own 5-state electrical machine @0x278 — 0=Starting,1=NoVoltage,2=Shorted,3=GeneratorOff,4=Ready per the string dump @4b1224 — do not confuse the two.)
|
||||
- Also in the preamble: `if (this+0x40 == 1) SetState(genState, 1)` — pins a +0x40==1 generator to Off every tick.
|
||||
- No gate on the trip: it fires at any experience level *mechanically*, but temperature can only rise when the heat model integrates (FUN_004ad7d4 gate = player+0x260, veteran+expert), so trips only occur when the heat model is on [T1].
|
||||
|
||||
### 2. THE RECOVERY — exact re-arm condition and threshold
|
||||
Case 4 body (part_013.c:9087-9097): output forced 0 every tick; `if (heatAlarm@0x184 == 0)`: if generatorOn@0x1D4==0 → SetState(1) Off; else → startTimer@0x1F0=0, SetState(0) **Starting** — then case 0 counts startTimer up and at startTime seconds does SetState(2) Ready + `outputVoltage = (1.0 − damageZone->damageLevel) × ratedVoltage` (constant @4b2154 byte-verified = 3F800000 = 1.0f in the exe's CODE section, file offset 0xB1F54).
|
||||
|
||||
**The re-arm threshold is NOT "half" of anything — there is no 0.5 multiplier anywhere in the generator path** (constants adjacent to the sim: @4b2154=1.0, @4b2158=0.0, @4b2258=1.0, @4b297c=0.0 — all byte-verified from BTL4OPT.EXE) [T1]. Recovery requires the heat alarm to return to **0 (NormalHeat), i.e. T ≤ DegradationTemperature** — alarm 1 (DegradationHeat) is NOT enough; the generator stays OUT through the whole degradation band. The hysteresis is structural: trip at T > FailureTemperature, re-arm at T ≤ DegradationTemperature, plus a full StartTime spin-up before voltage returns.
|
||||
|
||||
**The tester's "red portion of the heat bar gone" rule matches this EXACTLY in gauge terms**: the two-part temp bars normalize to FailureTemperature with the warn boundary at DegradationTemperature (warnPix = width·Degrade/Failure, value = CurrentTemperature — gauges-hud.md §TEMP/STATUS bar, @4c4170/@4c4724) [T1]. "Red gone" ⇔ T ≤ DegradationTemperature ⇔ the binary's re-arm condition. Whether that is numerically "half-cooled" depends on authored per-mech values; field notes (open-questions.md: generators equilibrate 1100–1500 K in the degradation band vs the ~2000 FailureHeat line) put Degrade/Failure ≈ 0.55 — approximately half [T3, authored temps not extracted from the archives].
|
||||
|
||||
### 3. WHICH EDGE the annunciator hears
|
||||
The stateAlarm machine IS a StateIndicator; SetState = FUN_0041bbd8: first line unconditionally copies current→old (+0x10←+0x14), and ONLY on an actual value change it stores the new state and synchronously fires all three watcher chains (+0x18 audio / +0x2C video / +0x40 gauge), each watcher's vtbl+0x14 (part_002.c:5510-5546) [T1]. So:
|
||||
- **stateAlarm 4 is written AT TRIP** (edge old=2→new=4 fires the audio chain the same tick T crosses FailureTemperature), **re-asserted every tick while out (edge-filtered no-ops, no re-fire), and REPLACED at recovery** by the edge 4→0 (Starting), followed StartTime seconds later by 0→2 (Ready). Nothing "clears" 4 separately; no write of 4 happens at recovery.
|
||||
- What SOUND plays on which edge is decided by the AUTHORED AudioStateTrigger record streamed from content, engine code AUDWTHR.cpp `AudioStateTrigger::StateChanged` [T0]: fires when `!inverseTrigger && new_state==triggerState` (ENTER edge) or `inverseTrigger && old_state==triggerState` (LEAVE edge), with optional exclude_state suppression. **Both keying modes exist in the engine.** A "Generator Out" sample keyed non-inverse on state 4 speaks at TRIP; one keyed inverse on 4 (or non-inverse on 0/2) speaks at RECOVERY. The binary/engine machinery emits both edges faithfully — if the field build speaks only at recovery, the discriminator is the authored trigger record (trigger_state / inverse_trigger / exclude_state for `Generator.GeneratorState`), which has NOT been dumped ([statecfg] via BT_ATTRBIND_LOG would capture it; no capture exists in scratchpad/docs). Note the port's GaugeAlarm54::SetLevel (heat.hpp:106) and StateIndicator layout (STATE.h: oldState@0x10/currentState@0x14) reproduce the binary semantics exactly, including the unconditional old←current copy — the port sim (powersub.cpp:1296 GeneratorSimulation) is a faithful transcription of @4b1f7c, so the mis-edged audio is NOT a divergence in the generator sim itself [T1].
|
||||
|
||||
### 4. "No Ready-case recompute" — CONFIRMED, with one refinement
|
||||
The switch in @4b1f7c has cases 0,1,3,4 and **NO case 2** — in Ready the sim touches nothing; outputVoltage is recomputed as `(1−damage)×rated` ONLY on the two Ready-ENTRY transitions (case 0 timeout @9069-9073, case 3 timeout @9081-9085) [T1]. Refinement: `Generator::HandleMessage` @4b21d0 ALSO recomputes `(1−damage)×rated` on ANY message id ≠ 4 (gated by player+0x274 ≠ 0, not-novice), and msg 4 (short) drives SetState(3)+shortTimer=0 when +0x40 ∈ {0,2} — so a message delivery is a third recompute path, but the crit distributor delivers damage without messaging the generator, so the decomp-reference claim stands for the destroyed-in-place case [T1].
|
||||
|
||||
### Bonus: a binary-authentic "stuck offline forever" candidate
|
||||
ToggleGeneratorOnOff @4b1ed0 (not-novice gate FUN_004ac9c8, press>0): toggling ON while the heat alarm ≠ 0 sets generatorOn=1 and startTimer=0 but deliberately does NOT SetState — it leaves the machine in whatever state it is in. If the pilot toggles a TRIPPED (state 4) generator OFF (→ state 1, generatorOn=0) and back ON while still hot (state stays 1, generatorOn=1), the machine is now in state 1 with generatorOn=1 — and case 1 has NO exit logic and NO thermal re-arm check. When the heat later cools to normal, nothing transitions: the generator stays offline indefinitely, recoverable only by another full off/on toggle pair after cooling, or by re-tripping to state 4 (whose case body honors generatorOn) [T1, pure case-walk — matches the tester's non-reproducing "stuck offline forever" one-off]. This is the same defect family as the "no Ready-case recompute" latch and the open-questions FailureHeat weapon brick (weaponAlarm 7 — a different machine, same alarm-latch pattern).
|
||||
--- KEY FACTS ---
|
||||
* stateAlarm 4 (GeneratorOut) has exactly ONE producer in the binary: the thermal breaker at the top of GeneratorSimulation @004b1f7c — `if (heatAlarm@0x184 == 2) SetState(genState@0x1FC, 4)` (part_013.c:9062-9064); it is written AT TRIP, held (edge-filtered) while out, and replaced 4→0→2 at recovery — no write of 4 occurs on the recovery edge [T1]
|
||||
* Re-arm condition (case 4 body @004b1f7c, part_013.c:9087-9097): heat alarm must return to 0 = NormalHeat, i.e. currentTemperature ≤ DegradationTemperature (res+0xE8) — NOT half of FailureTemperature; no 0.5 constant exists in the path (sim constants @4b2154=1.0f, @4b2158=0.0f, @4b2258=1.0f byte-verified in BTL4OPT.EXE CODE section) [T1]
|
||||
* Recovery is two-stage: 4→0 Starting (startTimer reset), then after StartTime (res+0x104) seconds 0→2 Ready with outputVoltage = (1.0 − damageZone->damageLevel) × ratedVoltage; if generatorOn@0x1D4==0 at cool-down it goes 4→1 Off instead [T1]
|
||||
* The heat alarm producer FUN_004ad924 (part_013.c:5638-5646) has NO hysteresis: >FailureTemperature→2, >DegradationTemperature→1, else 0, every tick; thresholds loaded by HeatSink ctor @004adda0 from res+0xE4/0xE8/0xEC (StartingTemperature/DegradationTemperature/FailureTemperature, parse @004ae150); alarm names @004ae050: Normal/Degradation/FailureHeat [T1]
|
||||
* The tester's era rule maps exactly: the gauge temp bars place the warn/red boundary at DegradationTemperature over a 0..FailureTemperature scale (warnPix = width·low/high, gauges-hud.md, @004c4170/@004c4724), so 'red portion gone' ⇔ T ≤ DegradationTemperature ⇔ the binary's re-arm threshold [T1]; numerically ≈0.55·Failure from field equilibrium notes (1100–1500 K degradation band vs ~2000 FailureHeat) [T3]
|
||||
* The audio edge is decided by AUTHORED content, not code: engine AudioStateTrigger::StateChanged (AUDWTHR.cpp) fires on ENTER (non-inverse: new_state==triggerState) or LEAVE (inverse: old_state==triggerState) with optional exclude_state; the state machine (FUN_0041bbd8, part_002.c:5510) fires its audio/video/gauge chains synchronously on every level CHANGE, old←current copied unconditionally first [T0/T1]
|
||||
* The authored AudioStateTrigger record for Generator.GeneratorState (trigger_state/inverse_trigger/exclude_state) has never been dumped — no [statecfg] capture exists in scratchpad or docs; BT_ATTRBIND_LOG would print it at load [T2 gap]
|
||||
* 'No Ready-case recompute' CONFIRMED: the @004b1f7c switch has cases 0,1,3,4 and no case 2; recompute happens only on Ready-entry (case 0/3 timeouts) and on Generator::HandleMessage @004b21d0 for any message id ≠ 4 when player+0x274 ≠ 0 (not-novice); msg 4 = short → SetState(3)+shortTimer=0 when this+0x40 ∈ {0,2} [T1]
|
||||
* Binary-authentic stuck-offline latch found: ToggleGeneratorOnOff @004b1ed0 turning ON while heatAlarm ≠ 0 sets generatorOn=1 WITHOUT a state transition; from state 1 (Off) there is no thermal re-arm path, so off→on toggling a hot tripped generator strands it offline after cooling until another cold toggle pair or a fresh alarm-2 trip [T1 case-walk, matches the tester's one-off]
|
||||
* Generator toggle and short handling are novice-locked: FUN_004ac9c8 = (player+0x274 == 0); the heat-model integration gate is player+0x260 (veteran+expert) via FUN_004ad7d4, but the alarm thresholding runs ungated [T1]
|
||||
* Consumer view for cross-checks: PoweredSubsystem sim @004b0bd0 maps source stateAlarm 3→own state 2 'Shorted', 1||4→3 'GeneratorOff', 2→restart via 0 'Starting'; own electrical state names @004b1224: 0 Starting/1 NoVoltage/2 Shorted/3 GeneratorOff/4 Ready (machine @+0x264, level @0x278 — distinct from the generator's @0x1FC/0x210) [T1]
|
||||
* The port's generator machinery is a faithful transcription: powersub.cpp:1296 GeneratorSimulation mirrors @004b1f7c line-for-line, GaugeAlarm54::SetLevel (heat.hpp:106) mirrors FUN_0041bbd8 including the unconditional old←current copy, and engine StateIndicator layout (oldState@0x10/currentState@0x14) matches — the generator sim is NOT the source of the mis-edged audio [T1]
|
||||
--- UNCERTAINTIES ---
|
||||
* The authored trigger_state/inverse_trigger/exclude_state for the Generator.GeneratorState AudioStateTrigger (and which SF2 preset/control it drives) is undumped content data — this alone determines whether 'Generator Out' speaks at trip or recovery in an authentic build; dump with BT_ATTRBIND_LOG=1 ([statecfg]/[trigcfg] lines) on a mech load
|
||||
* Whether the pod's SPOKEN 'Generator Out' warning even rides the AudioStateTrigger/SF2 path at all, versus a separate speech/annunciator system — not established in this lane
|
||||
* The semantics of gen+0x40 (port name simulationState): ==1 pins the machine to Off each tick and excludes the generator from eject-counting, but what writes 1 there is unlocated; decomp-reference's 'destroyed in place keeps stale Ready voltage' implies destruction does NOT set it — the two claims need reconciling
|
||||
* Actual authored Generator StartingTemperature/DegradationTemperature/FailureTemperature/StartTime values per mech are inside the compiled content archives (only the exe and L4GAUGE.CFG reference the key names as text); the ≈0.55 Degrade/Failure ratio is inferred from field equilibrium notes, not extracted values
|
||||
* Whether message id 4 ('short') is ever delivered to Generator::HandleMessage in normal play (vs the @004b11bc ForceShortRecovery direct-call path) — the message's producer was not traced
|
||||
* @004b2164 (Generator::DeathReset thunk cited by the port) sits in an export gap between @4b215c and @4b21d0 — shape assumed from the port comment, not read from pseudocode
|
||||
|
||||
|
||||
########## LANE 2 ##########
|
||||
LANE: the port's generator reconstruction (game/reconstructed/powersub.cpp + heat.cpp/hpp, engine AUDWTHR.cpp watchers).
|
||||
|
||||
== 1. Trip + recovery logic and thresholds ==
|
||||
|
||||
The generator thermal breaker lives in Generator::GeneratorSimulation, C:/git/bt411/game/reconstructed/powersub.cpp:1296-1372, a line-for-line transcription of the binary @004b1f7c (reference/decomp/all/part_013.c:9049-9107).
|
||||
|
||||
TRIP (powersub.cpp:1304-1312):
|
||||
```
|
||||
if (heatAlarm.GetLevel() == HeatSink::FailureHeat) // this+0x184 == 2
|
||||
{
|
||||
... BT_HEAT_LOG "[gen] <name> TRIPPED (T=...)" on the transition only ...
|
||||
stateAlarm.SetLevel(GeneratorOut); // SetLevel 4 -- called EVERY frame while FailureHeat holds
|
||||
}
|
||||
```
|
||||
Binary: `if (param_1[0x61] == 2) FUN_0041bbd8(param_1+0x7f, 4);` (part_013.c:9062-9064) [T1 exact match].
|
||||
|
||||
RECOVERY (powersub.cpp:1340-1357):
|
||||
```
|
||||
case GeneratorOut: // 4
|
||||
outputVoltage = 0.0f;
|
||||
if (heatAlarm.GetLevel() == HeatSink::NormalHeat) // this+0x184 == 0
|
||||
{
|
||||
if (generatorOn == 0) stateAlarm.SetLevel(GeneratorIdle); // 1 -- STAYS DOWN until manual toggle
|
||||
else { startTimer = 0.0f; stateAlarm.SetLevel(GeneratorStarting); } // 0 -> after StartTime secs -> SetLevel(2) Ready
|
||||
}
|
||||
```
|
||||
Binary: `case 4: if (param_1[0x61] == 0) { if (param_1[0x75]==0) SetLevel 1; else { [0x7c]=0; SetLevel 0; } }` (part_013.c:9087-9098) [T1 exact match].
|
||||
|
||||
The heat thresholds are NOT in the generator — they are the HeatSink heatAlarm drive at the tail of HeatSinkSimulation, heat.cpp:851-862: `T > failureTemperature -> FailureHeat(2); else T > degradationTemperature -> DegradationHeat(1); else NormalHeat(0)`. Binary @004ad924 tail is identical (`param_1[0x47] < T -> 2; param_1[0x46] < T -> 1; else 0`, temps @0x11C/@0x118) — NO hysteresis on either side [T1]. Both temperatures are authored per-subsystem resource fields ("DegradationTemperature"/"FailureTemperature"); their generator values live in the streamed .RES model data and were not dumped here.
|
||||
|
||||
CONSEQUENCE FOR THE ERA RULE ("back online when the red bar portion is gone / half-cooled"): the recovery gate is heatAlarm==0, i.e. T must fall BELOW degradationTemperature — the LOWER of the two thresholds, well below the trip point. The heat gauges bind CurrentTemperature with DegradationTemperature + FailureTemperature as zone markers (content/GAUGE/L4GAUGE.CFG:4434-4436 pattern), so if the bar's red zone starts at DegradationTemperature, "red gone" == the exact recovery gate and the port is ALREADY era-correct — which matches the tester's own runs 2 and 3 ("it did come back online after cooling halfway", scratchpad/night14/housekeep14.py:224-240). This is the binary's behavior byte-for-byte; there is nothing to change in the sim [T1 code, T3 for the red-zone==degradation mapping, unverified against the palette].
|
||||
|
||||
== 2. Where stateAlarm is written, and on which edge ==
|
||||
|
||||
All stateAlarm (alarm @0x1FC, level @0x210) writers in the port:
|
||||
- ctor powersub.cpp:1113 `SetLevel(GeneratorReady)` (2)
|
||||
- GeneratorSimulation trip :1311 `SetLevel(4)` — TRIP edge, re-asserted every held frame
|
||||
- GeneratorSimulation recovery :1346/:1354 `SetLevel(1)` or `SetLevel(0)`, then :1321 `SetLevel(2)` after StartTime — RECOVERY is TWO notify edges: 4->0, then 0->2
|
||||
- ToggleGeneratorOnOff :1212/:1221 (0 on healthy re-arm, 1 on switch-off)
|
||||
- ResetToInitialState :1269-1270 `SetLevel(0); SetLevel(2);` — every respawn fires a 0-then-2 notify pair (binary @004b215c does the same, part_013.c:9119-9120)
|
||||
- Generator::HandleMessage msg 4 :1392 `SetLevel(GeneratorShorted)` (3)
|
||||
- ForceShortRecovery (PoweredSubsystem) :555 and PowerWatcher::HandleMessage :1564 (both set 3)
|
||||
- MarkGeneratorOut (powersub.hpp:483) — documented UNUSED; the destruction bridge was removed as unfounded (powersub.hpp:471-481).
|
||||
|
||||
The notify mechanism: GaugeAlarm54::SetLevel (heat.hpp:106) `levelB = level; if (n != level) { level = n; NotifyWatchers(); }` — oldState updated unconditionally FIRST, watchers fired ON CHANGE ONLY. Binary FUN_0041bbd8 (part_002.c:5512-5546) is semantically identical: `+0x10 = +0x14` unconditionally, then if-changed set +0x14 and Execute() every watcher on the three chains @+0x18/+0x2c/+0x40 [T1]. So the per-frame SetLevel(4) spam while tripped notifies exactly once, at the 2->4 trip edge.
|
||||
|
||||
THEREFORE: the port's sim DOES deliver a watcher notification on the TRIP edge (old=2, new=4), and delivers two more on recovery (4->0, 0->2). The generator sim is not the component putting the audio on the wrong edge. There is NO ForceUpdate/SetDirty/updateModel mark at either edge — grep of powersub.cpp + heat.cpp is empty, and the binary @004b1f7c contains nothing but the SetLevel calls and arithmetic; the watcher chains ARE the notification path [T1].
|
||||
|
||||
AUDIO WIRING (adjacent, for synthesis): GeneratorState is published as an attribute directly on stateAlarm (powersub.cpp:1051, ATTRIBUTE_ENTRY(Generator, GeneratorState, stateAlarm)); the audio renderer binds authored AudioStateTriggers to it by name (context/wintesla-port.md:94, "audiostate skips 85 -> 0"). Trigger evaluation is engine T0 (engine/MUNGA/AUDWTHR.cpp:1046-1105): non-inverse fires when new_state==triggerState, INVERSE fires when old_state==triggerState (i.e. on LEAVING the state), with optional exclude pairs. Given the sim edges above, a sound heard ONLY at recovery means the live trigger fired on 4->0 or 0->2 — i.e. either an inverse trigger on state 4 ("leaving GeneratorOut") or a trigger on entering 0/2. Which of those is authored is in the streamed audio pages, NOT in the port code — undumped. BT_ATTRBIND_LOG=1 prints every AudioStateTrigger's `[statecfg] trigState/inv/ctl/excl` at bind time (AUDWTHR.cpp:981-987), and BT_HEAT_LOG prints "[gen] X TRIPPED"/"[gen] X RESTARTING" (powersub.cpp:1308-1311, 1350-1352); one capture correlating those against the heard sample settles the edge question definitively. Related suspicion [T4]: docs/AUDIO_FIDELITY.md F5/F6 document whole blocks of authored warning audio bound to dead attributes (ReportLeak is dead on GeneratorA-D among 19 subsystems, AUDIO_FIDELITY.md:402-411) — if the pod's trip-side warning rides one of those dead bindings, the trip would be silent in the port while a different, live authored cue (e.g. a spin-up/state sound at 4->0 or 0->2) is what the tester heard at recovery and labeled "the generator out warning".
|
||||
|
||||
== 3. Divergence vs the context claims ==
|
||||
|
||||
None found. context/decomp-reference.md:470-477 ("the generator sim has NO Ready-case recompute — a generator destroyed in place keeps stale Ready voltage until any transition recomputes output") is confirmed in both the port and the binary: the GeneratorSimulation switch has cases 0/1/3/4 only, no case 2 — outputVoltage is untouched while Ready [T1]. context/subsystems.md:103-105 ("(1 − generator damage) × rated, thermal breaker on FailureHeat, no load model") matches the transcription (the `(MaxOutputVoltage - SourceLevel()) * ratedVoltage` recomputes at :1322/:1336/:1398). The gnrator.cpp/gnrator.hpp pair is an alias note only — no second class, no code emitted (gnrator.cpp:10-24). One historical note: Generator::ResetToInitialState deliberately diverges from the surviving GNRATOR.TCP source (which zeroed outputVoltage) to follow the shipped binary @004b215c (outputVoltage = ratedVoltage) — documented at powersub.cpp:1238-1263 and docs/RESPAWN_REARM_PLAN.md:116 [T1].
|
||||
|
||||
== 4. FailureHeat "permanent brick" family (open-questions.md:1086-1102) ==
|
||||
|
||||
The generator does NOT share a recompute path with the weapon FailureHeat family — only the PREDICATE. All three families gate on the identical HeatSink heatAlarm level 2 at this+0x184 (open-questions.md:644-647, disasm-verified consumers), but their latch semantics differ:
|
||||
- Emitters (@004baa88): FailureHeat -> ResetFiringState + currentLevel=0 "until it cools" — SELF-RECOVERING.
|
||||
- Ballistic/missile launchers (@004bbd36 / projweap gate 1): FailureHeat -> weaponAlarm 7 (NoAmmo), re-asserted unconditionally inside the machine — a LATCH released only by an EjectAmmo tap or ResetToInitialState (the reproduced 19-rounds-left brick, open-questions.md:1086-1102).
|
||||
- Generator (@004b1f7c case 4): SELF-RECOVERING when heatAlarm returns to 0.
|
||||
So the missile roach-motel mechanism cannot produce the tester's once-seen "stuck offline forever" generator. Port-lane candidates for that non-reproducing report, both mechanisms [T1], scenario attribution [T4]: (a) the generatorOn==0 branch — if the pilot's generator toggle (RIO 0x1A-0x1D) had put generatorOn=0 (or was pressed while tripped: the OFF branch also zeroes coolantFlowScale, powersub.cpp:1219-1225, so the tripped generator loses its own coolant flow and cools only by conduction), a cooled generator lands in Idle(1) and NEVER self-restarts — authentic binary behavior requiring a manual toggle-ON; (b) a cooling stall — recovery needs T <= degradationTemperature (far below the trip point at failureTemperature); with coolant starved the last stretch can take a very long time, reading as "never" in one sitting while the heat BAR (which may visualize a different normalization) reads "cooled".
|
||||
--- KEY FACTS ---
|
||||
* Port trip gate: heatAlarm==FailureHeat(2) -> stateAlarm.SetLevel(GeneratorOut=4), powersub.cpp:1304-1312, re-asserted every frame while held; byte-matches binary @004b1f7c (part_013.c:9062-9064) [T1]
|
||||
* Port recovery gate: case GeneratorOut requires heatAlarm==NormalHeat(0), i.e. T <= degradationTemperature (the LOWER threshold), then 4->0 (Starting) -> after authored StartTime -> 0->2 (Ready); powersub.cpp:1340-1357 + 1316-1324; byte-matches binary part_013.c:9087-9098 [T1]
|
||||
* Heat alarm thresholds have NO hysteresis: T>failureTemperature->2, T>degradationTemperature->1, else 0; heat.cpp:851-862 == binary @004ad924 tail (temps @0x118/@0x11C) [T1]
|
||||
* GaugeAlarm54::SetLevel (heat.hpp:106) notifies watchers ON CHANGE ONLY, oldState updated unconditionally first — semantically identical to binary FUN_0041bbd8 (part_002.c:5512-5546); the per-frame SetLevel(4) spam produces exactly ONE trip-edge notification (old=2,new=4) [T1]
|
||||
* The port sim DOES fire a watcher notification on the trip edge; a sound heard only at recovery means the bound AudioStateTrigger fired on 4->0 or 0->2 — either an authored INVERSE trigger on state 4 (fires on old_state==triggerState, engine T0 AUDWTHR.cpp:1079-1082) or a trigger on entering Starting/Ready; the authored trigger config is in the streamed audio pages, undumped [T1 mechanics, config unknown]
|
||||
* No ForceUpdate/SetDirty/updateModel mark at either edge in port (grep empty over powersub.cpp+heat.cpp) or in binary @004b1f7c — the alarm watcher chains are the only notification path [T1]
|
||||
* GeneratorState attribute is published directly on stateAlarm (powersub.cpp:1051); audio binding verified live ('audiostate skips 85->0', context/wintesla-port.md:94-99) [T2]
|
||||
* decomp-reference.md 'no Ready-case recompute' CONFIRMED: the GeneratorSimulation switch has no case 2 in port or binary; outputVoltage stays stale while Ready [T1]; no divergence found between port and context/decomp-reference.md or context/subsystems.md generator claims
|
||||
* Generator does NOT share the weapon FailureHeat recompute/latch path — only the heatAlarm==2 predicate (this+0x184). Emitters @004baa88 self-recover, ballistic/missile @004bbd36 latch weaponAlarm 7 until EjectAmmo/reset (the reproduced brick, open-questions.md:1086-1102), generator self-recovers at heatAlarm==0 [T1]
|
||||
* Stuck-offline-forever candidates (mechanisms T1, attribution T4): generatorOn==0 at cool-down lands Idle(1) which never self-restarts (manual toggle required, authentic); toggling a generator OFF also zeroes its coolantFlowScale (powersub.cpp:1221-1224) starving its own cooling; recovery needs cooling all the way below degradationTemperature, far under the trip point
|
||||
* ResetToInitialState fires a 0-then-2 SetLevel pair on every respawn (powersub.cpp:1269-1270 == binary @004b215c) — any audio trigger keyed on entering state 0 or 2 also fires at every respawn [T1]
|
||||
* Era-rule alignment: heat gauges bind DegradationTemperature+FailureTemperature as zone markers (L4GAUGE.CFG:4434-4436 pattern); if the red zone starts at DegradationTemperature, 'red gone' == the recovery gate exactly — matching the tester's runs 2-3 recovery at half-cooled [T3]
|
||||
* Diagnostics that settle the audio edge: BT_ATTRBIND_LOG=1 dumps every AudioStateTrigger's trigState/inverse/exclude at bind (AUDWTHR.cpp:981-987); BT_HEAT_LOG prints [gen] TRIPPED/RESTARTING transition lines (powersub.cpp:1308-1311,1350-1352)
|
||||
--- UNCERTAINTIES ---
|
||||
* The authored AudioStateTrigger configuration for GeneratorState (trigger states, inverse flags, exclude pairs, control targets) is in the streamed audio pages of the mech model resources — not dumped; this single datum decides whether the recovery-edge sound is authored (inverse/state-0 trigger, pod would behave the same) or a port parsing/eval defect. Capture with BT_ATTRBIND_LOG=1.
|
||||
* Which sample the tester actually heard ('generator out warning') is unidentified — no GeneratorOut-named wav exists in audiopresets.cpp; it may be a Warnings01 klaxon split or another state cue misattributed. The trip-side warning may ride a DEAD authored binding (the AUDIO_FIDELITY F5/F6 family; ReportLeak is dead on GeneratorA-D) [T4].
|
||||
* Authored DegradationTemperature/FailureTemperature values for the generators (streamed .RES resources) not extracted; the 'red zone == degradation band' heat-bar mapping is inferred from the gauge attribute bindings, not verified against the palette rendering.
|
||||
* Whether the 1995 pod played the warning at the trip edge is era testimony only [T4]; nothing in the decomp examined here identifies the trip-side audio path.
|
||||
* The once-seen stuck-offline generator: neither candidate (generatorOn Idle landing, cooling stall) is confirmed against the tester's session — no log was captured for that run.
|
||||
|
||||
|
||||
########## LANE 3 ##########
|
||||
## #154 Generator Out warning — KB + field-evidence lane, raw findings
|
||||
|
||||
### 1. What the KB already claims (inventory)
|
||||
|
||||
**The generator state machine (binary-grounded):**
|
||||
- `stateAlarm` levels: 0=Starting, 1=Idle, 2=Ready/OnLine, 3=Shorted, 4=GeneratorOut. stateAlarm 4's producer = "the THERMAL BREAKER in GeneratorSimulation itself; a 2026-08-03 destruction→state-4 bridge was removed as unfounded" — `context/decomp-reference.md:470-477` [T1].
|
||||
- "The generator sim has NO Ready-case recompute — a generator destroyed IN PLACE keeps stale Ready voltage (no bit-6 invite) until any transition (thermal trip → stateAlarm 4 GeneratorOut, short, switch-off)" — `context/decomp-reference.md:472-475` [T1, @0049c9a8 + FUN_004b1f7c].
|
||||
- Offsets: `stateAlarm@0x1FC` (the 0x54 GaugeAlarm54 object base — `docs/HARD_PROBLEMS.md:251`, `docs/RESPAWN_REARM_PLAN.md:250`) vs `stateAlarm@0x210` in the eject clause (`decomp-reference.md:425`). These are CONSISTENT, not a conflict: 0x210 = 0x1FC + 0x14 = the alarm's `level` field (GaugeAlarm54 level@+0x14, `context/subsystems.md:31`). Flagging because it reads like a contradiction.
|
||||
- `Generator::ResetToInitialState @004b215c` does `stateAlarm.SetLevel(0)` then `SetLevel(2)` — "a forced *change*, so watchers re-latch" — `docs/RESPAWN_REARM_PLAN.md:172` [T1]. This 0→2 double edge fires at EVERY respawn/mission start.
|
||||
- Condition-flag bit table (the `[techstat]` receipts): bit0 structure≥StatusThreshold, bit1 structure>StatusFloor, bit2 CoolantLeaking, bit3 heatAlarm≠0 (Overheating), bit6 !HasVoltage (BadPower; HasVoltage = source stateAlarm==2 && |V|>ε @004b0b5c) — `decomp-reference.md:454-489` [T1]. Conditions are ROUTINE operating flags, not alarms; never read a lone SET as a latch [T2, field-verified 2026-08-08].
|
||||
- Audio binding: `Generator.GeneratorState`→stateAlarm registered as a real StateIndicator; "SetLevel fires them on change"; "generator/condenser/reservoir/ammo state sounds fire on transition" — `context/wintesla-port.md:87-99` [T2]. Port-side registration: `game/reconstructed/powersub.cpp:1051` `ATTRIBUTE_ENTRY(Generator, GeneratorState, stateAlarm)` with comment "SetLevel fires audio".
|
||||
- `simulationFlags` bit 0 = engine DelayWatchersFlag — "setting it permanently skips the subsystem's ExecuteWatchers (audio watchers)" — `decomp-reference.md:248-250` [T0/T1]. (A watcher-suppression footgun adjacent to this family.)
|
||||
- Experience gates: "generators take damage/go offline (reroute power)" is VETERAN+; standard mode = "no generator outages", MechTech audio limited to the leg-damage warning — `context/experience-levels.md:76-81` [T1 primary source].
|
||||
|
||||
**What the KB does NOT contain:** any claim about WHICH state edge the "Generator Out" audio is authored on, any decode of the authored AudioStateTrigger state→note records for GeneratorState, and any claim about the recovery threshold's relation to the heat bar. The recovery threshold itself was undocumented in `context/` prose — I read it from the decomp directly (below).
|
||||
|
||||
### 2. Binary + authored-data ground truth (read this session)
|
||||
|
||||
- **`FUN_004b1f7c` (GeneratorSimulation), `reference/decomp/all/part_013.c:9053-9107` [T1]:**
|
||||
- Trip: `if (heatAlarm.level==2 /*FailureHeat*/) SetLevel(stateAlarm, 4)` — runs EVERY tick while at FailureHeat; edge-firing therefore depends entirely on GaugeAlarm54::SetLevel's fire-on-change contract.
|
||||
- Recovery: `case 4:` exits ONLY when `heatAlarm.level == 0` (NormalHeat): generatorOn==0 → SetLevel(1) Idle; else `startTimer=0; SetLevel(0)` Starting → spin-up `startTime` → `SetLevel(2)` Ready + voltage restore. So a tripped generator stays out through the ENTIRE FailureHeat+DegradationHeat band and returns only when T ≤ degradationTemperature.
|
||||
- **Authored thresholds, raw `content/BTL4.RES` dump [T1]:** GeneratorA-D (classID 0xBC1, 0x10C records): startingTemp=77, degradationTemp=1000, failureTemp=2000 (all six mech variants identical). heatAlarm banding has NO hysteresis: >2000→2, >1000→1, else 0 (`game/reconstructed/heat.cpp:851-862`, transcribed from @004ad924).
|
||||
- **Therefore the binary's recovery point is T ≤ 1000 = exactly HALF of the 2000 trip line.** Oracle's era rule ("gens return at HALF-cooled / red bar gone") is not a missing feature — it is the shipped binary's arithmetic, and the port (`powersub.cpp:1296-1372`) transcribes it faithfully. The threshold audit flagged in the handout should come back "already authentic," CONTINGENT on one unverified visual claim: that the cockpit heat bar paints its red band as the ≥degradationTemp region (gauge-coloring not audited this pass) [T3 for the bar mapping].
|
||||
- **Recovery emits TWO SetLevel edges (4→0, then 0→2 after spin-up); trip emits ONE (x→4). RTIS emits the same 0→2 pair at every respawn/mission start (@004b215c, part_013.c:9119-9120).** Any audio cue keyed to entering state 0 or state 2 will sound at recovery AND at every respawn/round start; a cue keyed to entering state 4 sounds at trip. This is the structural fingerprint the wrong-edge bug must sit on [T1 for the edge structure; the authored state→sound mapping itself is UNREAD — that is the code/data lane's job].
|
||||
|
||||
### 3. The 1995 manual (primary source, pages read this session)
|
||||
|
||||
- **p23 (GENERATORS / Generator Info Center), verbatim:** "If a generator overheats, it will shut down. That generator will not come back on-line until its heat gauge has cooled down half way, which can take some time. If a generator is destroyed by a critical hit, an 'X' will appear in that generator's info center." — Oracle's era rule is PRINTED, word for word the half-way rule. Also feeds open era question #133 (the X = destroyed-by-crit, per the manual — not shutdown/overheat).
|
||||
- **p14 (MECHTECH / DAMAGE CONTROL):** the warning is listed among the spoken MechTech warnings: "*Warning, coolant leak … Warning, generator out … Warning, ammo bay fire*". MechTech audio warnings + smart buttons are veteran/expert-only; standard mode gets only the leg-damage message and "you are never required to switch generators".
|
||||
- **p19:** "when a generator overheats, it simply shuts down"; auto gen-mode cascade warning (all-auto + two dead gens can lock out sensors/myomers).
|
||||
- **p22:** "If your 'Mech stops moving, and the heat in your myomers is OK, check the generator; it may be the system that has overheated."
|
||||
- The warning is a VOICE line in 1995. **The port's SF2 banks contain no speech presets at all** (241 presets enumerated from `game/reconstructed/audiopresets.cpp`; the only warning-family presets are the `Warnings01` 8-way klaxon split and `AllWarning`). Whatever the tester hears as "Generator Out" in the port is a klaxon zone, not the spoken phrase — and where the original spoken phrases lived (not in AUDIO1/2.RES) is an unrecorded open question.
|
||||
|
||||
### 4. Field evidence (night15, 2026-08-10 steam logs, build 4.11.883)
|
||||
|
||||
- **The trip/recovery edges are FORENSICALLY INVISIBLE in field logs.** The only generator state receipts (`[gen] TRIPPED/RESTARTING`, powersub.cpp:1308-1352) are `BT_HEAT_LOG`-gated and appear 0 times in all six logs. No audio-warning receipts exist at all. #154's wrong-edge claim currently rests solely on Oracle's testimony + the manual; no log can confirm or refute it.
|
||||
- **Generator Overheating (cond 3) cycling is routine and balanced** — e.g. santo/MS-FIREFLY: ~30 GeneratorX cond-3 SETs with matching CLEAREDs; acaci/ZEUS GeneratorC 5 SET/4 CLEARED (log ends mid-heat). No latch anywhere = corroborates the stuck-forever non-repro.
|
||||
- **Probable real thermal trip captured (rajel/GAMERSLAB):** GeneratorB cond 3 SET :99453 (still set) → :103610-103625 ERSLaser_2 + ERPPC_2 cond 6 BadPower SET → cond 6 CLEARED :104109/:104273 → GeneratorB cond 3 CLEARED :104815 → re-SET :105025. **Note the ordering: the weapons regained voltage ~500-700 lines BEFORE the generator's Overheating flag cleared.** Under the binary model a same-generator recovery is impossible before heatAlarm→0, so this is either (a) manual/auto power rerouting to another generator (manual p14 procedure; the auto-hunt is live per `BT_POWER_DETACH_TEST` bench), or (b) an early-recovery defect. Logs cannot disambiguate (no per-weapon source receipts). Every other cond-6 cluster in the six logs traces to crit damage (gen cond 1+2 SET pairs = structure+coolant-leak flags, e.g. santo GeneratorD :107400/:107412) or to the mission-start spin-up wave (Dave :51669-52166: 11 subsystems BadPower while all gens run their startTime spin-up after load — clears in ~500 lines).
|
||||
- **The respawn reset clears gen conditions wholesale** (santo :89209-89210 GeneratorA cond 1+2 CLEARED inside the `[respawn] Mech::Reset` block) — and per @004b215c each respawn replays the 0→2 stateAlarm pair. If the port's warning cue is keyed to state 0 or 2, testers should ALSO hear it at every respawn/round start — a cheap discriminating question to put to Oracle.
|
||||
- **#135 adjacency receipt:** `[galarm] condition 2 code 0x80/0x87 sub 'GeneratorA/D' -> NO LAMP RESOLVED (generator=1)` — the generator-special lamp resolution path (@004cc27c power-family special) returns nothing for a leaking generator, so a generator coolant leak flashes NO annunciator. That is exactly Oracle's #135 ("coolant leak with NO flashing annunciators") signature on generators, in the current build's logs.
|
||||
|
||||
### 5. Prior-ticket / adjacent-defect map
|
||||
|
||||
- `docs/OPEN_ISSUES_FOR_TESTERS.txt:62-64` — #154 refined by Oracle: stuck-forever did NOT reproduce; era rule = half-cooled; "threshold audit due" (answer per §2: threshold already authentic).
|
||||
- #133 (open era question): the MFD X — manual p23 answers it: X = destroyed by critical hit.
|
||||
- The "missile spam trips FailureHeat permanent brick" (`context/open-questions.md:1086-1102`) is the WEAPON-side roach-motel: weaponAlarm 7 re-SetLevel(7) unconditionally (`decomp-reference.md:240-241`), a genuine latch. The GENERATOR breaker, by contrast, self-recovers by design. Different mechanism; only superficially the same family. If Oracle's once-seen "stuck offline forever" was real, the in-model candidates are: generatorOn==0 (state 4 → Idle requires a manual ToggleGeneratorOnOff; a pilot who punched the gen OFF while it was out stays dark forever — authentic), sustained load never letting T below 1000, or a coolant-leaked loop that can no longer shed heat at all.
|
||||
- #55/RESPAWN_REARM history: `Generator::RTIS` was once transcribed with `outputVoltage = 0` (stale GNRATOR.TCP) vs the binary's `= ratedVoltage` (`docs/RESPAWN_REARM_PLAN.md:116`) — a documented past hard-brick vector, since fixed (powersub.cpp now matches @004b215c).
|
||||
- git log has zero #154 commits — untouched territory.
|
||||
|
||||
### 6. Wrong-edge mechanism candidates (flagged for the code lane, all [T4] from this lane)
|
||||
1. The authored AudioStateTrigger record for `Generator.GeneratorState` keys the warning cue at state 0 (Starting) or 2 (Ready) rather than 4 — or the port misreads the authored state value when binding.
|
||||
2. The port's GaugeAlarm54 watcher passes the OLD level on change (off-by-one): a cue authored for level 4 then fires on the FIRST transition AFTER being at 4 — i.e. exactly at recovery. Symptom-exact.
|
||||
3. A Start/Stop inversion on a looped alarm cue (authored: start-on-enter-4 / stop-on-exit-4).
|
||||
Discriminator available without code: ask Oracle whether the same warning also sounds at respawn/round start (the RTIS 0→2 pair).
|
||||
--- KEY FACTS ---
|
||||
* Manual p23 verbatim: 'If a generator overheats, it will shut down. That generator will not come back on-line until its heat gauge has cooled down half way' — Oracle's era rule is printed 1995 doctrine (reference/manual/Tesla40_BT_manual.pdf p23) [T1 primary source]
|
||||
* Binary recovery threshold: GeneratorSimulation @004b1f7c case 4 exits ONLY at heatAlarm==0 (NormalHeat), i.e. T <= degradationTemp (reference/decomp/all/part_013.c:9087-9097) [T1]
|
||||
* Authored generator thresholds from raw BTL4.RES: startT=77, degradationTemp=1000, failureTemp=2000 for GeneratorA-D on all 6 variants — recovery at 1000 = exactly HALF the 2000 trip line, so the half-cooled rule is already the shipped arithmetic and the port transcribes it (powersub.cpp:1296-1372) [T1]
|
||||
* Trip emits ONE stateAlarm edge (x->4); recovery emits TWO (4->0 Starting, then 0->2 Ready after startTime); Generator::ResetToInitialState @004b215c replays the same 0->2 pair at every respawn/mission start (part_013.c:9119-9120) [T1]
|
||||
* The 'Warning, generator out' line is a spoken MechTech warning in 1995 (manual p14), veteran/expert only; the port's SF2 banks contain ZERO speech presets (241 enumerated, audiopresets.cpp) — whatever the port plays is a Warnings01 klaxon zone, and the original voice samples' home is unrecorded [T1/T2]
|
||||
* Audio path on file: Generator.GeneratorState -> stateAlarm bound as a real StateIndicator, 'SetLevel fires them on change' (context/wintesla-port.md:87-99; powersub.cpp:1051) [T2]; the authored state->note mapping for GeneratorState has never been decoded — the KB is silent on which edge the warning is authored to
|
||||
* Field logs (night15, all 6): zero receipts for generator stateAlarm transitions or audio warnings — [gen] TRIPPED/RESTARTING is BT_HEAT_LOG-gated and absent; #154's wrong-edge claim is currently unfalsifiable from logs [T2]
|
||||
* Probable thermal trip in rajel/GAMERSLAB: GenB cond3 SET :99453 -> ERSLaser_2+ERPPC_2 cond6 BadPower :103610 -> cond6 CLEARED :104109/:104273 BEFORE GenB cond3 CLEARED :104815 — weapons regained power while the gen was still hot; auto/manual reroute vs early-recovery defect not distinguishable from the log [T2]
|
||||
* Generator cond-3 SET/CLEARED counts are balanced in every night15 log (no latch) — corroborates Oracle's stuck-forever non-repro [T2]
|
||||
* Stuck-forever in-model candidate: state 4 with generatorOn==0 drops to Idle(1) and stays until a manual ToggleGeneratorOnOff — a pilot who toggled the gen off while it was out stays dark forever, authentically (part_013.c:9089-9091) [T1]
|
||||
* The missile-spam FailureHeat brick (open-questions.md:1086) is the WEAPON weaponAlarm-7 roach-motel (re-SetLevel(7) unconditionally, decomp-reference.md:240-241) — a real latch, mechanically distinct from the self-recovering generator breaker [T1]
|
||||
* #135 adjacency captured live: [galarm] condition 2 sub 'GeneratorA/D' -> NO LAMP RESOLVED (generator=1) in night15 logs — a generator coolant leak flashes no annunciator [T2]
|
||||
* stateAlarm@0x1FC vs @0x210 in the KB is NOT a contradiction: 0x1FC = GaugeAlarm54 base, 0x210 = its level field (+0x14) [T1]
|
||||
* Manual p23 answers open era question #133: the MFD X = generator destroyed by critical hit (not shutdown/overheat) [T1 primary source]
|
||||
* heatAlarm banding has no hysteresis (>2000->2, >1000->1, else 0; heat.cpp:851-862 from @004ad924), so recovery timing is purely the cooling curve crossing 1000 [T1]
|
||||
--- UNCERTAINTIES ---
|
||||
* Whether the cockpit heat bar's RED band is painted over the >=degradationTemp region (required for 'red gone' == the 1000 recovery line); gauge coloring was not audited this pass [T3]
|
||||
* Which authored state value the 'Generator Out' audio cue is keyed to — the AudioStateTrigger state->note records for GeneratorState are undecoded; all three wrong-edge mechanism candidates (cue keyed to state 0/2, old-level off-by-one in the watcher, Start/Stop inversion of a looped cue) are [T4] pending the code/data lane
|
||||
* Where the 1995 spoken warning phrases physically live (not in AUDIO1/2.RES SF2 banks) and what sample the port actually plays for the tester-heard 'Generator Out' warning — no audio receipt exists in any field log
|
||||
* Whether rajel's :103610 BadPower window cleared via auto-hunt/manual reroute (authentic) or an early same-generator recovery (defect) — indistinguishable without per-weapon voltage-source receipts
|
||||
* Which night15 log user is Oracle (handles: Dave/rajel/acaci/Michael/santo/eleng) — could not map the callsign, so the trip he described may not be in these six logs at all
|
||||
* Whether Oracle also hears the warning at respawn/round start (the RTIS 0->2 SetLevel pair) — a cheap testimony discriminator between the state-0/2-keyed and old-level hypotheses that has not been asked
|
||||
* Whether the binary's GaugeAlarm54 change-detection suppresses the per-tick SetLevel(4) re-fires during sustained FailureHeat exactly as the port's does (KB says fire-on-change [T1/T2]; not re-verified against disasm this pass)
|
||||
|
||||
|
||||
########## LANE 4 ##########
|
||||
## ANNUNCIATOR/AUDIO LANE — how stateAlarm 4 becomes (or fails to become) the audible "Generator Out" warning
|
||||
|
||||
### 1. The mechanism: state audio is EDGE-FIRED from SetLevel, not polled
|
||||
|
||||
Chain (all verified in code + binary):
|
||||
|
||||
1. `Generator::stateAlarm` is a `GaugeAlarm54` (the binary's 0x54 alarm, FUN_0041b9ec) at Generator+0x1FC; it IS a StateIndicator: stateCount@+0x0c, oldState@+0x10, currentState@+0x14, three watcher SChains @+0x18/0x2c/0x40 (C:\git\bt411\game\reconstructed\heat.hpp:93-139) [T1].
|
||||
2. `GaugeAlarm54::SetLevel(n)` (heat.hpp:106): `levelB = level; if (n != level) { level = n; NotifyWatchers(); }` — oldState is updated UNCONDITIONALLY, watchers fire only on a change. Byte-identical to the binary's Set_Alarm_Level @0041bbd8 (`*(p+0x10)=*(p+0x14)` unconditionally; on change, walk the three sockets calling vtbl+0x14 Execute) and to engine `StateIndicator::SetState` (C:\git\bt411\engine\MUNGA\SIMULATE.cpp:156-230) [T1/T0].
|
||||
3. `AudioStateWatcher` (C:\git\bt411\engine\MUNGA\AUDWTHR.cpp:886-919) registers DIRECTLY on the alarm's +0x18 audio socket (`Cast_Object(StateIndicator*,attributePointer)->AddAudioWatcher(this)`), NOT on any Simulation's audioWatcherSocket. So subsystem-state audio is synchronous with the SetLevel edge and never passes through `Simulation::ExecuteWatchers`. The binding resolves via `ATTRIBUTE_ENTRY(Generator, GeneratorState, stateAlarm)` (C:\git\bt411\game\reconstructed\powersub.cpp:1051); field log confirms real per-generator pointers, no pad redirects (`[attrbind] class=28 subsys=[GeneratorA] attr=[GeneratorState] -> ptr=052DC844`, C:\git\bt411\content\solo_20260729.log:39445) [T2].
|
||||
4. On a level change, `Execute()` (AttributeWatcherOf<StateIndicator>, C:\git\bt411\engine\MUNGA\WATCHER.h:265-327) compares its StateIndicator COPY (stateCount/oldState/currentState) to the live alarm, then `AudioStateWatcher::SendNotificationOfChange` calls `StateChanged(GetOldState(), GetState())`.
|
||||
5. `AudioStateTrigger::StateChanged` (AUDWTHR.cpp:1046-1105): fires `ReceiveControl(controlID, controlValue)` when `(!inverseTrigger && new_state==triggerState) || (inverseTrigger && old_state==triggerState)` — i.e. NON-INVERSE = "on ENTERING the state"; INVERSE = "on LEAVING the state". The binary's own StateChanged @0043eb40 (part_005.c:6960-6978, member map from ctor @0043e7d4: trig@+0x80, inv@+0x84, ctlID@+0x88, ctlVal@+0x8c, excl@+0x90/+0x94) is logic-identical, and the manifest attributes audwthr.cpp/.hpp code in the image to the surviving engine source (C:\git\bt411\reference\BT410_SOURCE_MANIFEST.md, "Engine/other TUs ... source survives") [T1].
|
||||
|
||||
### 2. THE CORE FINDING: the wrong-edge behavior is AUTHORED IN THE SHIPPED 1995 CONTENT, not a port defect
|
||||
|
||||
The shipped BTL4.RES streams exactly TWO AudioStateTriggers per generator on `GeneratorState`, decoded byte-exactly from C:\git\bt411\content\BTL4.RES @0x2be9a-0x2bf2a (GeneratorB records; A/C/D identical) and confirmed by the runtime dump (solo_20260729.log:39445-39448 etc.) [T1]:
|
||||
|
||||
- `trigState=1 (GeneratorIdle), inverse=0, control=Start(1)/0` — fires on ENTERING Idle.
|
||||
- `trigState=4 (GeneratorOut), inverse=1, control=Start(1)/0` — fires on LEAVING GeneratorOut.
|
||||
|
||||
There is NO trigger on entering state 4. Both triggers target the SAME non-looped warning sequence (comp=054135C0; `[seqcfg] ... looped=0 div=120 tempo=160 events=15`, notes 29/16/26 = Warnings01 zones z4/z0/z3 per C:\git\bt411\game\reconstructed\audiopresets.cpp:542-549), shared by all four generators. ControlID 1 = StartAudioControlID (C:\git\bt411\engine\MUNGA\AUDIO.h:81-95) [T1].
|
||||
|
||||
Cross-checked against the binary's GeneratorSimulation @004b1f7c (reference/decomp/all/part_013.c:9049-9110, matches C:\git\bt411\game\reconstructed\powersub.cpp:1296-1372 line for line) [T1]:
|
||||
|
||||
- THERMAL TRIP: heatAlarm==FailureHeat → `SetLevel(4)` from Ready(2) → StateChanged(2,4). Matches NO authored trigger → **the trip edge is silent, in the binary and in the port**.
|
||||
- RECOVERY: state 4 + heatAlarm==NormalHeat → `SetLevel(0)` (gen on, restart) → StateChanged(4,0) fires the inverse leave-4 trigger → **the warning sequence STARTS on the recovery edge**. (If the gen was switched off: 4→1 fires BOTH triggers — leave-4 AND enter-1.)
|
||||
- The when-it-DOES-play-at-"trip" cases: generator switched OFF LINE by the pilot (`ToggleGeneratorOnOff` → SetLevel(1), powersub.cpp:1221) and generator subsystem going destroyed/dead (`simulationState==1` → SetLevel(1) each tick, first transition fires) — both are enter-Idle, both play the warning at the moment of loss. Only the THERMAL breaker path (2→4) bypasses Idle and is silent until recovery.
|
||||
|
||||
So the port faithfully reproduces the shipped binary+content. Either the era pods really played the voice at thermal-recovery too (and the tester's memory conflates the destruction/switch-off cases, which DO play at loss), or the arcade floor ran a content revision whose GeneratorState triggers differ from this repo's BTL4.RES [T4 — cannot distinguish from the repo].
|
||||
|
||||
Authoring-intent evidence AGAINST the shipped config being intended: a census of ALL 118+ authored state triggers (solo_20260729.log statecfg dump) shows inverse triggers are otherwise used almost exclusively as `inv=1 ctl=2 (Stop)` loop-terminators (WeaponState 3-, 0-, AmmoState 3-leave → Stop). The generators' `inv=1 ctl=1 (Start)` rows are the ONLY subsystem-fault inverse-STARTs in the game (the sole other inverse-Start is Entity.AnimationState leave-1, a legitimate play-on-exit). A one-bit authoring slip (inverse_trigger=1 on a trigger meant as enter-4) fits the pattern; the era rule would then be restored by flipping that one authored flag in our stream/decode path — but that is a deviation from shipped content, flagged, not proposed [T1 census / T4 intent].
|
||||
|
||||
### 3. DelayWatchersFlag / updateModel — RULED OUT for this bug
|
||||
|
||||
- `AudioStateTrigger` never registers with `Simulation::AddAudioWatcher`; only `AudioTriggerOf`/`AudioMatchOf`/`AudioDeltaOf`/`AudioScaleOf` do (AUDWTHR.h:293, 770, 925, 535). `AreWatchersDelayed()` gates ONLY `Simulation::PerformAndWatch → ExecuteWatchers` (SIMULATE.cpp:459-479, mech4.cpp:8377) — the polled watchers. It CANNOT suppress one SetLevel edge and pass another; both trip and recovery notifications ride the same synchronous socket walk. [T0]
|
||||
- What a stuck DelayWatchersFlag on the Generator sim WOULD kill: the two `GeneratorOn` AudioLogicalTriggers (match 1/match 0 → Start ctl1/0.5 — the polled on/off cue) and the ReportLeak matchers, silently and permanently (the projweap/mislanch `simulationFlags|=1` trap, C:\git\bt411\game\reconstructed\projweap.cpp:461,1049). Nothing in the generator path sets it — the known setters are the weapon-family bugs already fixed, plus the btplayer.cpp:622-642 diagnostic. `updateModel|=1` (ForceUpdate) is the replication dirty mark only; no bearing on watchers. [T1]
|
||||
|
||||
### 4. The heat bar / "red portion gone" — the recovery gate ALREADY equals red-gone
|
||||
|
||||
- The generator panel's temperature bar is a `VertTwoPartBar` bound (value=CurrentTemperature, low=DegradationTemperature, high=FailureTemperature) — GeneratorCluster ctor @004c746c, C:\git\bt411\game\reconstructed\btl4gau2.cpp:980-998; config `GeneratorCluster(... sgentemp.pcc, 9, 11 ...)` at C:\git\bt411\content\GAUGE\L4GAUGE.CFG:5046 [T1].
|
||||
- `VertTwoPartBar::Execute` (@004c48fc, C:\git\bt411\game\reconstructed\btl4gaug.cpp:1318-1360): bar spans 0..FailureTemperature; tile bitmap below the warn line (DegradationTemperature), the FILL COLOR segment is drawn ONLY for [warnPix, valPix) — i.e. the colored ("red") portion exists exactly while CurrentTemperature > DegradationTemperature. "Red portion gone" ⇔ T ≤ DegradationTemperature [T1].
|
||||
- The recovery gate is `heatAlarm.GetLevel()==NormalHeat` (powersub.cpp:1342), and heatAlarm is a pure no-hysteresis threshold ladder recomputed every HeatSinkSimulation tick: T>failure→2, T>degradation→1, else 0 (C:\git\bt411\game\reconstructed\heat.cpp:851-862, @004ad924) [T1].
|
||||
- Therefore the generator leaves GeneratorOut on the EXACT tick the red portion of its bar disappears — the tester's era rule is already the implemented (and binary-authentic) threshold. The visible lag: leaving 4 enters Starting(0), voltage stays 0 for the authored StartTime spin-up before Ready(2) — so power (voltage bar/weapons) returns startTime seconds AFTER red-gone; that delay is authentic. Whether DegradationTemperature is numerically "half" of FailureTemperature is per-mech authored data in the streamed subsystem resources (not stored as text; not extracted) [T3].
|
||||
- No-hysteresis corollary: a generator that keeps making heat can duty-cycle across the degradation threshold (trip→cool→restart→re-trip), playing the warning once per RECOVERY — a repeating warning that never coincides with a trip, which plausibly amplified the tester's wrong-edge perception. The "stuck offline forever" non-repro is consistent: exit requires only T ≤ degradationTemperature with the sim ticking; a true brick needs dissipation to be structurally gone (the open-questions "missile-spam FailureHeat brick" entry is about heat delivery, not this audio path).
|
||||
|
||||
### 5. Cross-check: alarms that DO play on their trip edge, and what differs
|
||||
|
||||
Nothing differs in code — one shared `AudioStateTrigger::StateChanged` serves all; the difference is purely the authored trigger rows:
|
||||
- Condenser: `trigState=1 inv=0` AND `trigState=2 inv=0` → Start (ctl 1/4) — fires on ENTERING each fault state (trip edge). [T1, statecfg census]
|
||||
- AmmoBin: enter-3 Start + leave-3 Stop (loop pair, cook-off countdown), enter-4 Start, enter-5 Start — trip-edge Starts, inverse used only as Stop. [T1]
|
||||
- Reservoir: enter-1 Start. Weapons: enter-N Starts, inverse-Stop loop terminators. [T1]
|
||||
- Generator alone has its fault state (4) authored ONLY with an inverse (leaving) Start, and its enter-Start sits on Idle(1) instead of Out(4). [T1]
|
||||
--- KEY FACTS ---
|
||||
* Subsystem state audio is edge-fired synchronously from GaugeAlarm54::SetLevel/StateIndicator::SetState walking the alarm's own +0x18 audio socket (heat.hpp:106, heat.cpp:96-111, SIMULATE.cpp:156-230, binary @0041bbd8) — it never passes through Simulation::ExecuteWatchers [T1]
|
||||
* AudioStateTrigger semantics: non-inverse fires on ENTERING triggerState (new_state==trig); inverse fires on LEAVING it (old_state==trig) — engine source AUDWTHR.cpp:1079-1104 [T0], byte-confirmed in the binary @0043eb40 with member map from ctor @0043e7d4 [T1]
|
||||
* Shipped BTL4.RES authors exactly two GeneratorState triggers per generator: (state 1 Idle, inv=0, Start) and (state 4 GeneratorOut, inv=1, Start) — decoded from BTL4.RES bytes @0x2be9a-0x2bf2a and matching the runtime [statecfg] dump (content/solo_20260729.log:39445-39448); there is NO trigger on entering state 4 [T1]
|
||||
* Thermal trip (heatAlarm==FailureHeat -> SetLevel(4), Ready 2->4, @004b1f7c == powersub.cpp:1304-1312) matches no authored trigger -> trip edge is SILENT in both the port and the 1995 binary; recovery (4->0 or 4->1) fires the inverse leave-4 Start -> the reported wrong-edge behavior is the shipped content+engine behavior, not a port defect [T1]
|
||||
* The warning plays at the moment of LOSS only for the enter-Idle paths: pilot switch-off (SetLevel(1), powersub.cpp:1221) and subsystem-dead simulationState==1 (powersub.cpp:1302) [T1]
|
||||
* Both generator triggers on all four generators target one shared non-looped sequence (notes 29/16/26 = Warnings01 zones z4/z0/z3, audiopresets.cpp:542-549); controlID 1 = StartAudioControlID (AUDIO.h:83) [T1]
|
||||
* DelayWatchersFlag (simulationFlags bit 0) gates only polled watchers (ExecuteWatchers, SIMULATE.cpp:472-474); it cannot suppress one SetLevel edge and pass another; on a generator it would instead silently kill the polled GeneratorOn on/off matchers [T0/T1]
|
||||
* Authoring census: inverse triggers elsewhere are almost exclusively inv=1+Stop loop terminators; the generators' inv=1+Start on a fault state is unique among subsystem alarms — consistent with a one-flag authoring slip in the 1995 content [T1 census, T4 intent]
|
||||
* Generator heat bar (VertTwoPartBar @004c48fc, btl4gau2.cpp:980-998): colored fill exists only while CurrentTemperature > DegradationTemperature, so 'red portion gone' == T <= DegradationTemperature == exactly the existing recovery gate (heatAlarm NormalHeat, heat.cpp:851-862, no hysteresis) — the tester's era rule for the return threshold is already implemented; only the authored StartTime spin-up delays visible power return [T1]
|
||||
* heatAlarm has no hysteresis, so a heat-producing generator can duty-cycle trip/restart, replaying the warning once per RECOVERY [T1]
|
||||
--- UNCERTAINTIES ---
|
||||
* Whether the arcade-floor pods ran a content revision whose GeneratorState audio triggers differ from this repo's BTL4.RES — the era-rule claim (voice at thermal trip) contradicts the shipped authoring we have; cannot be settled from the repo [T4]
|
||||
* Sample identity of Warnings01 zones z4/z0/z3 (notes 29/16/26) — assumed to be the audible 'Generator Out' voice/klaxon material; not verified by listening [T3]
|
||||
* Authored DegradationTemperature/FailureTemperature values per mech (whether 'red gone' is numerically HALF-cooled) — baked into streamed subsystem resources, not extracted [T3]
|
||||
* Replicant-side behavior (whether a passenger/other pod hears the warning on the same edges) — out of this lane, untraced
|
||||
* No field log with BT_HEAT_LOG active captures an actual trip/recovery temperature pair, so the duty-cycle amplification of the wrong-edge perception is mechanism-derived, not field-observed [T3]
|
||||
|
||||
|
||||
---
|
||||
|
||||
## Phase 2 — adversarial verification (two skeptic lanes)
|
||||
|
||||
#### VERIFIER 0 ####
|
||||
ADVERSARIAL VERIFICATION OF #154 "two triggers, no enter-4" — ATTACK FAILED ON THE DECODE; PARTIAL HIT ON THE BEHAVIORAL CLAIM.
|
||||
|
||||
== 1. Read order: source vs binary vs port — NO DIVERGENCE [T1] ==
|
||||
T0 source (engine/MUNGA/AUDWTHR.cpp:974-979): AudioStateTrigger ctor reads triggerState, inverseTrigger, controlID, controlValue, excludeTransition, excludeState, after the base chain reads subsystem CString, attribute CString, sendNotificationOnChange (WATCHER.cpp:60,91,145), dump_value (WATCHER.h:212), audio_component ObjectID (AUDWTHR.h:151). All ints/enums are 4 bytes (STYLE.H:132,137; AUDIO.h:98 AudioControlValue=Scalar float); CString = len(4)+bytes+NUL (CSTR.cpp:353-356).
|
||||
Binary: ctor @0043e7d4 reads six consecutive 4-byte fields into +0x80..+0x94 after base @0043e738. Field MEANINGS (not just positions) are pinned by StateChanged @0043eb40: +0x80 is the state comparand, +0x84 the inverse boolean (selects old-vs-new comparison), +0x88/+0x8c go to ReceiveControl, +0x90/+0x94 the exclude pair, with the exclude-clause structure exactly mirroring the source. Writer @0043e8a4 emits name-list keys in the same order (trigger_state, inverse_trigger, control_ID, control_value, exclude_state).
|
||||
The one attack surface the prior analysis never checked — the CALLER's argument order — also holds: SendNotificationOfChange @0043e79c passes (watcher+0x30, watcher+0x34); the snapshot filler @0041bb88 copies indicator +0x0c/+0x10/+0x14 = stateCount/oldState/currentState, so arg1=oldState, arg2=newState, matching the source. Had the caller passed (new,old), the inverse trigger WOULD have fired on enter-4 (audible trip) — this was the only single-fault reinterpretation that could rescue the testers' expectation, and it is excluded by the binary's own code.
|
||||
|
||||
== 2. Independent byte re-decode (my parser, from the exe-verified layout, not the port's) ==
|
||||
Record A @0x02be8f: classID=0x1c, objID=0x033b @0x2be93, "GeneratorB" (len@0x2be97), "GeneratorState" (len@0x2bea6), sendNotif=1 @0x2beb9, dump=0 @0x2bebd, comp objID=0x032f @0x2bec1; trigger fields @0x2bec5: trigState=1 @0x2bec5, inverse=0 @0x2bec9, controlID=1(Start) @0x2becd, controlValue=0.0 @0x2bed1, exclTrans=0 @0x2bed5, exclState=0 @0x2bed9.
|
||||
Record B @0x02bedd: objID=0x033c, same strings, comp=0x032f; fields @0x2bf13: trigState=4 @0x2bf13, inverse=1 @0x2bf17, controlID=1(Start) @0x2bf1b, controlValue=0.0 @0x2bf1f, exclTrans=0 @0x2bf23, exclState=0 @0x2bf27 (record ends 0x2bf2b — the prior's cited window 0x2be9a-0x2bf2a is these two records).
|
||||
Structural proof of the layout: my strict parser recovered 2306 valid class-0x1c records file-wide with contiguous record chaining, sane enums, and printable strings — impossible under a shifted/swapped layout. RES-wide census: ALL 144 GeneratorState triggers (4 gens x 36 vehicle pages) are exactly the two shapes (1,inv0,Start) and (4,inv1,Start). No enter-4 anywhere, no Stop, no exclude. The prior analysis's decode is CORRECT.
|
||||
|
||||
== 3. State numbering — 0-based, verified against the binary sim and LIVE receipts ==
|
||||
The binary's generator sim FUN_004b1f7c writes raw levels through SetState @0041bbd8 with no translation: heatAlarm==2 -> SetLevel(4) (thermal breaker); switch cases 0/1/3/4; recovery from 4 -> SetLevel(0) (gen on) or SetLevel(1) (gen off). Authored trigState compares verbatim against these [T1, binary-internal, port-independent].
|
||||
Calibration: AmmoState authored set {enter-0 Start (feed whir), leave-0 Stop, enter-1 Start, enter-2 Start, enter-3 Start + leave-3 Stop, enter-4 Start/1, enter-5 Start/3} maps 1:1 onto ammobin.hpp levels 0=Feeding..5=Dumped; LIVE receipts in content/genedge.log: edge 0->3 fired enter-3 Start, edge 3->2 fired leave-3 Stop AND enter-2 Start — inverse semantics and 0-based numbering confirmed live. Condenser: authored enter-1/enter-2 Start/4 matches sim writes 1(degraded)/2(severe)/0(normal) (heatfamily_reslice.cpp:1443-1445).
|
||||
CORRECTION to the prior analysis: its "AmmoBin cook-off enter-3/leave-3" label is WRONG — AmmoState 3 is EJECTING (eject-hold countdown loop); the cook-off warning is gated on FireCountdownStarted match watchers (ammobin.hpp:104-134). The calibration still works; the label must be fixed.
|
||||
If authored trigState were 1-based: (1,inv0)->enter-Starting(0), (4,inv1)->leave-Shorted(3) — STILL no enter-4. Swapped trig/inverse fields on record B (payload 4,1) -> fire-on-leaving-state-1 — still no enter-4, and it would garble hundreds of other records (AnimationState trig=23 would become inverse=23). The ONLY reinterpretation putting a Start on ENTER GeneratorOut(4) is flipping the inverse semantics (inv=1 = fire on new==trig), excluded at T1 by @0043eb40 + @0043e79c/@0041bb88 and by the live AmmoState receipts (flipped semantics would start the eject loop on RELEASE).
|
||||
|
||||
== 4. VERDICT: the decode is SOLID [T1]; the behavioral conclusion is UNDER-EVIDENCED ==
|
||||
The two-trigger/no-enter-4 authoring is now confirmed by three mutually independent routes (T0 source, binary pseudocode semantics, my own byte decode) plus a live semantics calibration. It is not a parser echo chamber anymore.
|
||||
HOWEVER, two things keep the prior CONCLUSION short of certain, and give the testers room to be right:
|
||||
(a) The live trip observation NEVER HAPPENED: content/genedge.log (the #154 bench, run 2026-08-11 06:30) contains ZERO [gen] TRIPPED/RESTARTING lines and zero GeneratorState 2->4 or 4->x [audioedge] edges — the BT_GEN_HEAT injection did not take effect (bench's own verdict: INCONCLUSIVE). "Warning plays on recovery" in the port is still a static prediction. The only generator edges captured live are 0->2 power-ups, which correctly fire nothing.
|
||||
(b) "Silent by authoring" does not mean "testers hear a consistent nothing at trip": the recovery paths are asymmetric (4->0 fires ONE Start; 4->1 fires TWO Starts — leave-4 AND enter-1 — on the SAME component 0x32f), the GeneratorOn logical match watchers fire Start/0.5 on BOTH edges ([matchcfg] receipts), the 38-watcher ReportLeak warning family is known-dead (AUDIO_FIDELITY.md F6), and genedge.log shows a real delivery quirk: old=3 new=3 same-state deliveries fired BOTH the Start and the Stop of one loop (root: SetState/SetLevel writes oldState unconditionally even on no-change — binary @0041bbd8:5520 does the same, and the polling compare @0041bba8 includes oldState — so it may be authentic, but the port's polling cadence vs the binary's is unverified). Any of these is a credible source of "wrong AND inconsistent" without the RES decode being wrong.
|
||||
To call it certain: re-run scratchpad/night15/gen_edge_bench.sh with the heat injection actually reaching the sim (verify the BT_GEN_HEAT gate: generatorNumber==1 && viewpoint entity; confirm the EGG's vehicle carries GeneratorA) and capture trip-edge no-fire + recovery-edge FIRED; identify what sample/sequence audio component 0x32f actually plays (warning klaxon vs generator spin-up whine — decides whether the authored intent was ever a "warning" at all); ideally, one original-cab/emulator recording of a thermal trip as behavioral ground truth.
|
||||
KEY FACTS:
|
||||
* Read order identical across T0 source (AUDWTHR.cpp:974-979), binary ctor @0043e7d4 (+0x80..+0x94), and the port; field meanings pinned semantically by @0043eb40 (StateChanged) and the writer @0043e8a4
|
||||
* Caller argument order verified: @0043e79c passes (oldState,newState) — snapshot filled by @0041bb88 from indicator +0x10/+0x14; a swapped order was the only decode fault that could make the trip audible, and it is excluded
|
||||
* Independent re-decode of BTL4.RES @0x2be8f/@0x2bedd: (trigState=1,inv=0,Start) and (trigState=4,inv=1,Start) on GeneratorB.GeneratorState, comp 0x32f — matches the prior analysis exactly; all field offsets stated (fields @0x2bec5 and @0x2bf13)
|
||||
* RES-wide census (my parser, 2306 class-0x1c records): all 144 GeneratorState triggers are the same two shapes; no enter-4 trigger exists anywhere in the file
|
||||
* State numbering is 0-based and raw: binary sim FUN_004b1f7c writes SetLevel 0/1/2/3/4 with 4=thermal breaker; recovery 4->0 (gen on) or 4->1 (gen off); no translation layer anywhere
|
||||
* Live calibration receipts (content/genedge.log): AmmoState 0->3 fired enter-3 Start, 3->2 fired leave-3 Stop + enter-2 Start — inverse semantics and numbering confirmed at runtime
|
||||
* PRIOR-ANALYSIS ERROR FOUND: AmmoState level 3 is Ejecting (eject-hold countdown), NOT cook-off; the cook-off klaxon is gated on FireCountdownStarted match watchers (ammobin.hpp:104-134)
|
||||
* The #154 live bench never observed a trip: genedge.log (2026-08-11) has 0 TRIPPED/RESTARTING lines and no 2->4/4->x edges — BT_GEN_HEAT injection did not take effect; 'recovery fires the warning' is still static-only for the port
|
||||
* Candidate explanations for 'inconsistent' tester reports that do NOT require a decode error: asymmetric recovery (4->1 double-Start vs 4->0 single), GeneratorOn match watchers firing Start on both edges, dead ReportLeak warning family (AUDIO_FIDELITY.md F6), and live same-state deliveries (old=3 new=3) firing Start+Stop pairs due to the unconditional oldState write in SetState (@0041bbd8, mirrored by port GaugeAlarm54::SetLevel)
|
||||
UNCERTAINTIES:
|
||||
* Whether the port's recovery edge actually fires the sequence live (T2 missing): the gen_edge_bench must be re-run with BT_GEN_HEAT actually reaching GeneratorSimulation (the 2026-08-11 run shows zero [gen] lines — injection gate or vehicle/generator naming issue)
|
||||
* What audio component 0x32f (runtime 054135C0) actually plays — a warning sequence or the generator spin-up/idle sound; this decides whether 'warning plays on recovery' is even the right characterization of the authored intent
|
||||
* Whether the same-state (old==new) Start+Stop double-delivery seen live is authentic 1995 behavior at the same frequency — the binary has the identical unconditional oldState write and snapshot compare, but the port's polling cadence vs the binary's notify path is unverified
|
||||
* Whether the 1995 cab sounded anything else at thermal trip via non-AudioStateTrigger paths (heat-alarm audio, gauge alarm streams, cockpit MFD alerts) — outside this decode's scope but inside the testers' perception
|
||||
* GeneratorState level-name labels (0=Starting,1=Idle) are best-effort [T3] per powersub.hpp — the numbering is certain, the English names are not
|
||||
|
||||
#### VERIFIER 1 ####
|
||||
VERDICT: The prior analysis's AUTHORING DECODE SURVIVES verification, but its CONCLUSION ("thermal trip silent, warning on recovery, therefore behavior is consistent-by-authoring") is REFUTED on three grounds: (1) it was never runtime-verified — the #154 bench (scratchpad/night15/gen_edge_bench.sh -> content/genedge.log) contains ZERO "[gen] TRIPPED"/"RESTARTING" receipts, so no trip or recovery edge was ever observed live; the recovery-edge claim is code-derived [T1], not [T2]; (2) the enter-Idle trigger makes the SAME 3-tone sequence fire on at least five different game events with opposite meanings, four of them not mentioned by the prior analysis; (3) three field-measured port mechanisms make even correctly-fired warnings intermittent.
|
||||
|
||||
== 1. THE COMPLETE EVENT->SOUND TABLE (generator warning sequence = AudioControlSequence, 3 notes 29/16/26 = Warnings01_z4(loop)/z0/z3, ~3.25 s at div=120 tempo=160; ONE sequence component SHARED by all four generators A-D — solo_20260729.log:39452-39476, all four statecfg rows target comp 054135C0) ==
|
||||
Authored triggers per generator (verified in both logs, excl=0/0 so NO exclude-transition clause): T-A trigState=1 inv=0 ctl=Start/0 (fires on ANY entry to state 1) and T-B trigState=4 inv=1 ctl=Start/0 (fires on ANY exit from state 4). GeneratorState enum [T1, powersub.hpp:377-388]: 0=Starting 1=Idle 2=Ready 3=Shorted 4=Out.
|
||||
- Mission start / ResetToInitialState (SetLevel(0);SetLevel(2), powersub.cpp:1269-1270): edges (x,0),(0,2) -> SILENT (bench-confirmed: 4x "old=0 new=2 ... no-fire" in genedge.log).
|
||||
- THERMAL TRIP 2->4 (powersub.cpp:1341, per-frame while heatAlarm==FailureHeat): SILENT. Prior analysis correct on this edge. But outputVoltage collapses -> !HasVoltage status bit (stateAlarm==4 read, powersub.cpp:1836) -> masterAlarm/MechTech + gotoEngineering gauge invite CAN sound at trip [T3 — masterAlarm edges are live in the bench log but the specific generator condition->voice line was not traced]. Testers hearing a VOICE at trip and the TONE 10-60 s later at recovery = "timing feels wrong".
|
||||
- THERMAL RECOVERY 4->0 (generatorOn==1, powersub.cpp:1384): T-B FIRES — warning tone announces power RETURNING. One tone per generator recovery; four generators trip/recover STAGGERED, and each Start on the shared sequence STOPS and RESTARTS it from t=0 (AUDSEQ.cpp:409-412 StartSequence stops-if-running; StopSequence chases pending Stops, cutting the current note) -> stuttered/truncated warnings whose count varies with heat spread. A player riding the heat edge gets a periodic tone on EVERY trip/recover duty cycle — always at the recovery, never at the loss.
|
||||
- RECOVERY WHILE SWITCHED OFF 4->1 (powersub.cpp:1376): BOTH T-A and T-B fire — double Start same frame (second restarts the sequence).
|
||||
- PILOT TOGGLES GENERATOR OFF (ToggleGeneratorOnOff, powersub.cpp:1221, byte-matched to @004b1ed0): x->1, T-A FIRES — the "generator out" warning plays for a deliberate heat-management action (authentic, but a tester counts it as spurious). Toggle ON: SetLevel(0) only if heat healthy — silent; if heat-degraded, NO state write at all (silent, state stays at fault).
|
||||
- GENERATOR CRIT-DEATH: no direct SetLevel on the crit path (BTGeneratorMarkOut has ZERO callers — the powersub.cpp:483 method is documentation-only; hpp:471 says the ForceCriticalFailure bridge was removed), BUT GeneratorSimulation's pin `if (simulationState==1) SetLevel(GeneratorIdle)` (powersub.cpp:1330-1332, authentic @004b1f7c) fires T-A on the next tick: 2->1 (or 4->1 = DOUBLE fire if it died tripped). So a generator LOSS by crit DOES play the warning — one frame late — directly contradicting "loss is silent by authoring".
|
||||
- SHORT 2->3 and short-recovery 3->2 (powersub.cpp:1422,1365): SILENT both ways.
|
||||
- RESPAWN WITH A TRIPPED GENERATOR: ResetToInitialState SetLevel(0) delivers (4,0) -> T-B FIRES the warning right at respawn; dying un-tripped respawns silent. Inconsistent respawn audio depending on how you died. [T1 code-read, unbenched]
|
||||
- GeneratorOn POLLED MATCHERS (AudioLogicalTrigger, solo log: match=1 -> ctl1(Start)/0.5 and match=0 -> ctl1(Start)/0.5, per generator): generatorOn is init 1 and written ONLY by the toggle (powersub.cpp:1214,1222) and reset (=1). Thermal trip does NOT touch it. So: bind-time prime fires the match=1 Start (spawn hum — every AudioMatchOf subclass ctor calls PrimeWatcher, and AudioMatchOf::SendNotificationOfChange has no edge memory: it fires whenever notified AND equal, AUDWTHR.h:818-848); manual OFF fires the match=0 Start (a second sound stacked on the T-A warning). Target components unidentified (matchcfg does not print comp) — [T4 what they sound like].
|
||||
|
||||
== 2. INTERMITTENCY MECHANISMS (the "inconsistent" the testers report) ==
|
||||
A. VOICE STEAL / TRUE DROP AT COMBAT PEAK [T2, field-measured]: L4AUDRND.cpp:1287-1409 — on channel exhaustion the incoming Start steals only from LOWER-weight running sources (transient victims are STOPPED mid-play, sustained SUSPENDED); if nothing outranks, the Start is genuinely dropped (gBTAudioTrueDrops). The 2026-08-10 field logs show up to 932 steals and 22-30 acquire-failure prints per session (scratchpad/night15/steam_20260810_f_eleng_ALIA.log). Heat trips correlate exactly with peak firefight + heat klaxon + MechTech voices, so the 3-note warning's Starts land in the most contended window: any of its three notes can be stolen mid-sequence or dropped. AUDIO_FIDELITY.md F3 adds that steal/cull/ducking are DISTANCE-BLIND in the port (AL linear model), further randomizing which source loses.
|
||||
B. TRANSIENT-START VOLUME CULL: AUDREND.cpp:236-251 silently discards any Start on a transient source whose volume scale < LowAudioVolumeThreshold (0.3), and AUDREND.cpp:175-193 discards Starts on clipped transient sources entirely. Whether the cockpit warning target (seq tgt comp) is transient was not determined [T4]; if it is, this is a second silent-drop gate.
|
||||
C. BIND-TIME PRIME FIRES TRIGGERS [T2, bench-observed]: AudioStateTrigger ctor calls PrimeWatcher() (AUDWTHR.cpp:989) -> GrabCurrentValue -> StateChanged(alarm.oldState, alarm.currentState) at bind. Combined with the GaugeAlarm54::SetLevel oldState-clobber (heat.hpp:106 — `levelB = level` runs even when the level does NOT change, so any state that is re-set per frame reads old==new), a trigger bound while its alarm sits AT trigState fires BOTH polarities immediately: genedge.log lines 878/881 show "[audioedge] old=3 new=3 trig=3 inv=0 ... FIRED" AND "inv=1 ... FIRED" during a mid-run mech build. For generators this is benign at normal spawn (state 2) but fires the warning on any bind/rebuild that catches state 1 or 4.
|
||||
D. THE T3 BRING-UP GUARD CAN SILENTLY UNPLUG A GENERATOR'S STATE AUDIO: AUDWTHR.cpp:893-917 skips AddAudioWatcher when the bound alarm's +0x18 socket reads 0/0xCDCDCDCD — permanently silent for that subsystem, logged only under BT_AUDIO_LOG. GeneratorState binds with vtbl=00000000 (raw GaugeAlarm54 header) in every log; registration currently succeeds (edges were delivered in the bench), but the guard makes generator audio construction-order-dependent — a latent per-mech/per-build inconsistency [T3].
|
||||
E. DelayWatchersFlag: gates ONLY the polled watchers (Simulation::Simulate, SIMULATE.cpp:472; mech4.cpp:8377) — i.e. the GeneratorOn/ReportLeak matchers — NOT the state triggers (those are called directly from the alarm's NotifyWatchers, heat.cpp:96-111). RequestEncore sets it (SIMULATE.cpp:727) and only the encore path clears it (UPDATE.cpp:213-215). The historical bug (death path setting bit 0, permanently muting a player's polled audio) is fixed and canary-guarded (btplayer.cpp:635-643). No current generator-warning exposure, but a regression would kill the GeneratorOn sounds while leaving the state warning alive — a plausible past contributor to "inconsistent" reports depending on build vintage.
|
||||
|
||||
== 3. CROSS-POD / REPLICANT ==
|
||||
Replicant mechs DO build audio objects (interest teardown destroys them — context/multiplayer.md interest-teardown crash section [T2]), and subsystems DO tick on replicants when executable (#148 instance branch, mech4.cpp:8077-8104). Whether a replicant's Generator ever reaches state 1/4 locally depends on whether heat state feeds its sim — per-subsystem heat is not replicated (damage is master-side only per the #45 note), so remote generator warnings should not track the remote pilot's actual thermal state [T3]. Remote sources are also subject to the clip/volume gates, so at typical ranges they are inaudible. An observer/passenger riding a REPLICANT viewpoint would NOT hear that mech's authentic generator warnings (its master simulates elsewhere) [T3].
|
||||
|
||||
== 4. WHAT SURVIVES OF THE PRIOR ANALYSIS ==
|
||||
The RES decode itself is confirmed at runtime: exactly two AudioStateTriggers per generator, trigState=1/inv=0/Start and trigState=4/inv=1/Start, excl=0/0, both targeting the shared 3-note sequence (solo_20260729.log:39445+ and genedge.log both match). "The trip edge 2->4 fires nothing" is true [T1]. Everything downstream of that — "therefore silent-by-authoring at loss, warning on recovery, consistent" — is refuted: crit-loss sounds (via the sim-state pin), manual OFF sounds, respawn-after-tripped sounds, recoveries stutter-restart a shared sequence, and the delivery/rendering pipeline drops or truncates the sound under exactly the conditions in which trips happen. RECOMMENDED NEXT STEP: re-run gen_edge_bench (it never tripped — zero [gen] receipts; verify the BT_GEN_HEAT injection actually reaches the viewpoint Generator A and the build contains the injection block), and add a crit-death + toggle + respawn leg to capture the T-A firings live.
|
||||
KEY FACTS:
|
||||
* The #154 bench log content/genedge.log contains ZERO '[gen] TRIPPED' or 'RESTARTING' receipts — the thermal trip/recovery edge mapping was NEVER observed live; the prior conclusion is code-derived [T1], not runtime-verified
|
||||
* All four generators (A-D) share ONE warning sequence component (statecfg comp=054135C0 in solo_20260729.log:39452-39476); AudioControlSequence::StartSequence stops-and-restarts if already running (AUDSEQ.cpp:409-412), so staggered per-generator recoveries stutter/truncate the warning
|
||||
* GeneratorState enum: 0=Starting 1=Idle 2=Ready 3=Shorted 4=Out (powersub.hpp:377-388); authored triggers: enter-1 Start and leave-4 Start, no exclude clauses (excl=0/0)
|
||||
* The enter-Idle trigger fires the SAME warning on: generator crit-death (simulationState==1 pin, powersub.cpp:1330-1332), pilot toggling a generator OFF (powersub.cpp:1221), and recovery-while-off 4->1 (double-fire with the inverse trigger)
|
||||
* ResetToInitialState does SetLevel(0);SetLevel(2) (powersub.cpp:1269-1270): a mech that died with a tripped generator (state 4) fires the warning AT RESPAWN via the 4->0 edge; dying un-tripped respawns silent
|
||||
* GaugeAlarm54::SetLevel (heat.hpp:106) clobbers oldState unconditionally (levelB=level even when unchanged) and notifies only on change; per-frame same-level SetLevel therefore makes old==new at the alarm
|
||||
* Every concrete audio trigger ctor calls PrimeWatcher() at bind, which delivers StateChanged(old,cur) unconditionally; bench lines show old==new deliveries that FIRED both trigger polarities (genedge.log '[audioedge] old=3 new=3 trig=3 ... FIRED' for inv=0 AND inv=1) — a trigger bound while its alarm sits at trigState fires spuriously
|
||||
* Voice contention is live in current builds: 2026-08-10 field logs show up to 932 voice steals and 22-30 acquire failures per session (scratchpad/night15/steam_20260810_f_eleng_ALIA.log); the steal loop stops transient victims mid-play and true-drops unrankable Starts (L4AUDRND.cpp:1287-1409)
|
||||
* Transient Starts are silently discarded when clipped or below LowAudioVolumeThreshold=0.3 (AUDREND.cpp:175-251), and the cull is distance-blind (AUDIO_FIDELITY.md F3)
|
||||
* The AudioStateWatcher bring-up guard (AUDWTHR.cpp:893-917) silently skips watcher registration on an unconstructed alarm socket — construction-order-dependent permanent silence for that subsystem's state audio [T3 latent]
|
||||
* DelayWatchersFlag gates only POLLED watchers (GeneratorOn/ReportLeak matchers), never the alarm-socket state triggers; the historical death-path bit-0 bug is fixed and canary-guarded (btplayer.cpp:635-643)
|
||||
* GeneratorOn is written ONLY by the pilot toggle and reset — a thermal trip does NOT clear it; its two matchers both issue Start (ctl1/0.5): match=1 at bind/toggle-ON, match=0 at toggle-OFF
|
||||
* BTGeneratorMarkOut has zero call sites — generator crit-death does NOT SetLevel(4); the warning at crit-death comes from the simulationState==1 Idle pin one tick later
|
||||
* Thermal trip zeroes outputVoltage -> !HasVoltage status bit (stateAlarm==4, powersub.cpp:1836) -> masterAlarm/MechTech + gotoEngineering invite can sound AT TRIP while the tone sequence sounds at RECOVERY — a perception split for testers
|
||||
UNCERTAINTIES:
|
||||
* Why the bench never tripped: BT_GEN_HEAT=50000 for 25 s should exceed FailureTemperature — either the injection block wasn't in the running build, the viewpoint-entity/generatorNumber gate didn't match, or the run window missed; needs a re-run before ANY edge claim is called verified
|
||||
* Whether the warning sequence's target source (tgt comp, e.g. 0540FA18) is TransientAudioRenderType — determines exposure to the volume-cull and clip drop gates (AUDREND.cpp:175-251)
|
||||
* The exact source of the REPEATED old==new deliveries to the same comps in genedge.log (lines 814/978/1030): interpreted as bind-time primes of successive identical weapons sharing sequence comps during a mid-run mech build; not traced to completion — an unidentified re-prime/re-execute path would widen mechanism C to mid-life spurious warnings (including old=4,new=4 firing the warning DURING a trip)
|
||||
* What the GeneratorOn matchers' Starts (ctl1/0.5) actually sound like — [matchcfg] does not print the target component; needs a matchfire capture or RES decode of those pages
|
||||
* Whether a MechTech VOICE line specifically fires on the generator !HasVoltage condition at trip time in the port (masterAlarm is live, but the condition->voice mapping for generator-out was not traced) [T3]
|
||||
* Whether replicant Generator subsystems ever reach state 1/4 in MP (per-subsystem heat is believed master-side only) and whether their warning sequences route to spatialized sources or a center-channel path — the passenger/observer-seat audio experience is unaudited
|
||||
* Whether destroyed generators keep ticking GeneratorSimulation long enough for the simulationState==1 pin to deliver its edge in every case (DoNothingOnce/NeverExecute latching order at subsystem death)
|
||||
* Whether any encore/re-stream path rebinds audio pages mid-round (which would prime-fire triggers against in-state alarms); NotifyOfReplacementEntityCreation is Fail('under construction') so late re-creation may be impossible today
|
||||
|
||||
Reference in New Issue