Joe DiPrima
25ed1ca627
#21 closed at the true root + 'arcade shipped a brick' RETRACTED (era witnesses 6-0): _DAT_004ba830 is a DOUBLE 1.0, not float 0.0 -- the entire brick claim was a constant-width misread (dword read of a qword; the low half of 1.0's mantissa is zeros). Binary truth [T1 raw disasm @004ba738]: overcharge CLAMPS to exactly 1.0f, the ==1.0 Loaded test passes next tick, the weapon fires the stored charge at normal top-gear damage (divisor is the recommended gear). Fix: clamp corrected to 1.0f; the rescue scaffolding REMOVED (it patched our own misread -- 38 'rescues' were 38 events the machine silently clamped); gauge-side zeroing inherits the fix, which is almost certainly #21's ORIGINAL field symptom (dark recharge arc + dark ready-dot = the dial reading our zeroed ratio while the rescue kept the weapon firing). seek21 bench PASS: 65 switches / 16 wraps / 9 overcharges -> fires through all, 13 post-overcharge gauge probes FULL, zero rescue prints. Docs: field guide section 2 rewritten as settled-by-testimony (credit to the group), decomp-reference block retracted with extracted constants, drift audit energy lane -> FAITHFUL, ZERO deviations. The witnesses' 'nah, that didn't happen' was worth eight bytes read at full width
2026-08-13 17:59:24 -05:00
..
2026-07-05 21:03:40 -05:00
2026-08-13 16:41:18 -05:00
2026-07-05 21:03:40 -05:00
2026-07-05 21:03:40 -05:00
2026-07-26 17:06:00 -05:00
2026-07-26 17:06:00 -05:00
2026-07-21 23:38:25 -05:00
2026-07-26 02:49:30 -05:00
2026-08-11 20:29:20 -05:00
2026-08-11 18:37:59 -05:00
2026-07-30 10:10:29 -05:00
2026-08-10 11:29:01 -05:00
2026-07-27 16:08:10 -05:00
2026-07-07 11:49:58 -05:00
2026-08-06 10:22:50 -05:00
2026-08-11 00:27:47 -05:00
2026-08-11 00:27:47 -05:00
2026-08-11 01:58:23 -05:00
2026-07-26 09:06:58 -05:00
2026-08-13 02:14:13 -05:00
2026-07-28 19:23:29 -05:00
2026-07-29 15:49:39 -05:00
2026-07-07 22:19:50 -05:00
2026-08-11 02:33:14 -05:00
2026-08-07 11:22:47 -05:00
2026-07-05 21:03:40 -05:00
2026-08-06 10:22:50 -05:00
2026-07-24 15:05:06 -05:00
2026-07-18 00:05:51 -05:00
2026-07-31 09:17:31 -05:00
2026-07-21 08:49:58 -05:00
2026-07-05 21:03:40 -05:00
#21 closed at the true root + 'arcade shipped a brick' RETRACTED (era witnesses 6-0): _DAT_004ba830 is a DOUBLE 1.0, not float 0.0 -- the entire brick claim was a constant-width misread (dword read of a qword; the low half of 1.0's mantissa is zeros). Binary truth [T1 raw disasm @004ba738]: overcharge CLAMPS to exactly 1.0f, the ==1.0 Loaded test passes next tick, the weapon fires the stored charge at normal top-gear damage (divisor is the recommended gear). Fix: clamp corrected to 1.0f; the rescue scaffolding REMOVED (it patched our own misread -- 38 'rescues' were 38 events the machine silently clamped); gauge-side zeroing inherits the fix, which is almost certainly #21's ORIGINAL field symptom (dark recharge arc + dark ready-dot = the dial reading our zeroed ratio while the rescue kept the weapon firing). seek21 bench PASS: 65 switches / 16 wraps / 9 overcharges -> fires through all, 13 post-overcharge gauge probes FULL, zero rescue prints. Docs: field guide section 2 rewritten as settled-by-testimony (credit to the group), decomp-reference block retracted with extracted constants, drift audit energy lane -> FAITHFUL, ZERO deviations. The witnesses' 'nah, that didn't happen' was worth eight bytes read at full width
2026-08-13 17:59:24 -05:00
#21 closed at the true root + 'arcade shipped a brick' RETRACTED (era witnesses 6-0): _DAT_004ba830 is a DOUBLE 1.0, not float 0.0 -- the entire brick claim was a constant-width misread (dword read of a qword; the low half of 1.0's mantissa is zeros). Binary truth [T1 raw disasm @004ba738]: overcharge CLAMPS to exactly 1.0f, the ==1.0 Loaded test passes next tick, the weapon fires the stored charge at normal top-gear damage (divisor is the recommended gear). Fix: clamp corrected to 1.0f; the rescue scaffolding REMOVED (it patched our own misread -- 38 'rescues' were 38 events the machine silently clamped); gauge-side zeroing inherits the fix, which is almost certainly #21's ORIGINAL field symptom (dark recharge arc + dark ready-dot = the dial reading our zeroed ratio while the rescue kept the weapon firing). seek21 bench PASS: 65 switches / 16 wraps / 9 overcharges -> fires through all, 13 post-overcharge gauge probes FULL, zero rescue prints. Docs: field guide section 2 rewritten as settled-by-testimony (credit to the group), decomp-reference block retracted with extracted constants, drift audit energy lane -> FAITHFUL, ZERO deviations. The witnesses' 'nah, that didn't happen' was worth eight bytes read at full width
2026-08-13 17:59:24 -05:00